A new method for estimating knee joint flexion/extension angles from segment acceleration and angular velocity data is described. The approach uses a combination of Kalman filters and biomechanical constraints based on anatomical knowledge. In contrast to many recently published methods, the proposed approach does not make use of the earth's magnetic field and hence is insensitive to the complex field distortions commonly found in modern buildings. The method was validated experimentally by calculating knee angle from measurements taken from two IMUs placed on adjacent body segments. In contrast to many previous studies which have validated their approach during relatively slow activities or over short durations, the performance of the algorithm was evaluated during both walking and running over 5 minute periods. Seven healthy subjects were tested at various speeds from 1 to 5 mile/h. Errors were estimated by comparing the results against data obtained simultaneously from a 10 camera motion tracking system (Qualysis). The average measurement error ranged from 0.7 degrees for slow walking (1 mph) to 3.4 degrees for running (5 mph). The joint constraint used in the IMU analysis was derived from the Qualysis data. Limitations of the method, its clinical application and its possible extension are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2009.08.004DOI Listing

Publication Analysis

Top Keywords

inertial sensor-based
4
sensor-based knee
4
knee flexion/extension
4
flexion/extension angle
4
angle estimation
4
estimation method
4
method estimating
4
estimating knee
4
knee joint
4
joint flexion/extension
4

Similar Publications

Evaluating walkability across age groups and flooring materials using IMU sensors.

Front Public Health

December 2024

Department of Architectural Engineering, Dankook University, Yongin-si, Gyeonggi-do, Republic of Korea.

This study presents a novel approach to quantitatively assess the impact of flooring materials on walkability using Inertial Measurement Unit (IMU) sensors and Dynamic Time Warping (DTW) algorithm. Four common pavement materials (wood, asphalt, concrete block, and cement) were evaluated across five age groups (20-30, 30-40, 40-50, 50-60, and over 60 years) with 80 participants walking 1,200 m on each surface. IMU sensors attached to the lumbar region recorded acceleration and gyroscope data, which were then analyzed using DTW to quantify gait stability.

View Article and Find Full Text PDF

An Empirical Model-Based Algorithm for Removing Motion-Caused Artifacts in Motor Imagery EEG Data for Classification Using an Optimized CNN Model.

Sensors (Basel)

November 2024

Humanitarian Technology (HuT) Labs, Department of Electronics and Communication Engineering, Amrita Vishwa Vidyapeetham, Amritapuri 690525, India.

Article Synopsis
  • EEG is a non-invasive, portable technique widely used in brain-computer interfaces (BCIs) to help individuals with severe mobility issues control devices like wheelchairs through motor imagery signals.
  • The study introduces a new approach for enhancing the quality of EEG recordings by addressing motion artifacts, which traditional methods struggle with, especially for users in motion.
  • Utilizing a modified CNN deep learning algorithm and considering real-world variables, the research achieved a high classification accuracy of 94.04% in distinguishing movements, showcasing its effectiveness for practical BCI applications.
View Article and Find Full Text PDF
Article Synopsis
  • * A scoping review conducted between late 2023 and early 2024 identified and summarized findings from 31 studies exploring various types of wearable sensors and their effectiveness in fall risk prediction models.
  • * It recommends using specific sensors in certain body positions and suggests that while certain walking tests are useful, further empirical research is necessary to optimize the models for community application.
View Article and Find Full Text PDF

Background: Reliable lameness thresholds for vertical head displacement for trotting on a circular path and on different surfaces have yet to be defined. Withers movement in lame horses could help improve the diagnostic accuracy of sensor technology.

Objectives: To define head movement lameness threshold ranges and describe the relationship between head and withers movement during trotting under different circumstances in sound and forelimb lame horses.

View Article and Find Full Text PDF

Background: Fatigue manifests as a decline in performance during high-intensity and prolonged exercise. With technological advancements and the increasing adoption of inertial measurement units (IMUs) in sports biomechanics, there is an opportunity to enhance our understanding of running-related fatigue beyond controlled laboratory environments.

Research Question: How have IMUs have been used to assess running biomechanics under fatiguing conditions?

Methods: Following the PRISMA-ScR guidelines, our literature search covered six databases without date restrictions until September 2024.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!