Objectives: The aim of this study was to assess prosthesis/annulus discongruence and its impact on the occurrence of significant aortic regurgitation (AR) immediately after transcatheter aortic valve implantation (TAVI).
Background: Paravalvular AR might occur after TAVI, but its determinants remain unclear.
Methods: Comprehensive echocardiographic examinations were performed in 74 patients who underwent TAVI with a balloon expandable device. Congruence between annulus and device was appraised with the cover index: 100 x (prosthesis diameter - transesophageal echocardiography annulus diameter)/prosthesis diameter.
Results: At baseline aortic valve area was 0.67 +/- 0.2 cm(2), and mean gradient was 50 +/- 15 mm Hg. The TAVI used transfemoral approach in 46 patients (62%) and transapical access in 28 (38%). Prosthesis size was 23 mm in 24 patients (34%) and 26 mm in 50 patients (66%). After TAVI, paravalvular AR was absent in 5 patients (7%), graded 1/4 in 53 (72%), 2/4 in 12 (16%), and 3/4 in 4 (5%). Occurrence of AR >or=2/4 was related to greater patient height, larger annulus, and smaller cover index (all p < 0.002) but not to ejection fraction, severity of stenosis, or prosthesis size. AR >or=2/4 was never observed in patients with aortic annulus <22 mm or with a cover index >8%. Significant improvements were observed from the first 20 cases (AR >or=2/4, 40%) to the last 54 (AR >or=2/4, 15%) (p = 0.02). In multivariate analysis, independent predictors of AR >/=2/4 were low cover index (odds ratio: 1.22; per confidence interval: 1.03 to 1.51 per 1% decrease, p = 0.02) and first versus last procedures (odds ratio: 2.24; 95% confidence interval: 1.07 to 5.22, p = 0.03).
Conclusions: Our study shows that the occurrence of AR >or=2/4 is related to prosthesis/annulus discongruence even after adjustment for experience. Hence, to minimize paravalvular AR, appropriate annular measurements and prosthesis sizing are critical.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcin.2009.07.003 | DOI Listing |
J Soc Cardiovasc Angiogr Interv
December 2024
Cardiovascular Institute, Detroit Medical Center, DMC Heart Hospital, Detroit, Michigan.
Transcatheter aortic valve repair (TAVR) presents a minimally invasive alternative to traditional surgical valve replacement, albeit not without its own set of complications. A rare complication is the infolding of the self-expanding valve, which can precipitate cardiac arrest. The estimated incidence rate of this complication stands at 1.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Medicine, Michael E DeBakey Veteran's Affairs Medical Center, Houston, Texas, USA.
Transcatheter aortic valve replacement (TAVR) has become a viable treatment option for patients with severe aortic stenosis among all risk subsets. As TAVR use becomes more prevalent and patients live longer with their transcatheter valve, an increasing number of these patients can be expected to present with ACS. Overall, there is a paucity of high-quality data detailing incidence, pathophysiology, and management of ACS in this subset.
View Article and Find Full Text PDFZhonghua Xin Xue Guan Bing Za Zhi
January 2025
Cardiology Department, Second Affiliated Hospital of Dalian Medical University, Dalian116021, China.
To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.
View Article and Find Full Text PDFRen Fail
December 2025
Center for Cardiac Intensive Care, Beijing Anzhen Hospital, Capital Medical University, Beijing Institute of Heart, Lung and Blood Vessel Diseases, Beijing, China.
Background: The incidence of acute kidney injury (AKI) increases after surgical aortic valve replacement (SAVR). This study aimed to characterize the risk factors of AKI after SAVR.
Methods And Results: We conducted a retrospective registry study based on data from 299 consecutive patients undergoing SAVR.
Background: Surgical aortic valve replacement (SAVR) is the commonly used approach for aortic valve replacement (AVR) in patients with aortic stenosis at low or intermediate surgical risk. However, transcatheter aortic valve replacement (TAVR) has emerged as an alternative to SAVR for AVR. This meta-analysis aims to assess the comparative efficacy and safety of TAVR versus SAVR in low-to-intermediate surgical risk patients by analyzing temporal trends in the outcomes of TAVR and SAVR at various follow-up intervals, providing a more detailed understanding.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!