A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection of Plasmodium vivax infection in the Republic of Korea by loop-mediated isothermal amplification (LAMP). | LitMetric

Loop-mediated isothermal amplification (LAMP) is a novel technique that rapidly amplifies target DNA in isothermal conditions. In a previous study, the sensitivities and specificities of LAMP, microscopy, and nested PCR were compared in the context of rapid malaria detection. In the present study, LAMP detected vivax malaria parasites in 115 of 117 microscopically positive samples (sensitivity, 98.3%; 95% CI, 97.4-100%), which agreed well with the nested PCR results (sensitivity, 99.1%; 95% CI: 96.0-100%). No positive cases of malaria were detected by LAMP or nested PCR in 50 consecutive feverish patients other than malaria from malaria endemic areas. LAMP performed on DNA extracted from heat-treated blood had a sensitivity of 93.3% (28/30, 95% CI: 84.4-100%) and specificity of 100% (30/30, 95% CI: 100%). The present study shows that LAMP based assays have high sensitivity, specificity, and amplification efficiencies for Plasmodium vivax detection. The authors recommend that LAMP can be considered as a rapid nucleic acid amplification assay for the molecular diagnosis of P. vivax in both clinical laboratories and malaria clinics in areas where vivax malaria is endemic.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actatropica.2009.09.007DOI Listing

Publication Analysis

Top Keywords

nested pcr
12
plasmodium vivax
8
loop-mediated isothermal
8
isothermal amplification
8
lamp
8
amplification lamp
8
study lamp
8
vivax malaria
8
malaria endemic
8
malaria
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!