A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improvement of the accuracy in the optical hematocrit measurement by optimizing mean optical path length. | LitMetric

Improvement of the accuracy in the optical hematocrit measurement by optimizing mean optical path length.

Artif Organs

Cybernics Laboratory, Systems and Information Engineering, University of Tsukuba, Tsukuba, Ibaraki, Japan.

Published: September 2009

Optical techniques have been developed to acquire blood information (e.g., hematocrit [Hct], saturation of oxygen, thrombus) noninvasively and continuously in an artificial heart. For the practical use of an optical Hct measurement, Twersky's theory has been shown to be useful and have a good agreement in forward-scattered measurements. However, it was not applied to backward-scattered measurements, which can provide the measurement with a less demanding spatial requirement. Additionally, optimal measurement for accuracy is not well examined. Therefore, we developed an accurate Hct measurement in an artificial heart using current optical devices. To this end, we focused on optimizing an emitter-detector distance to provide a maximum optical path length. We attached optical emitter and detector fibers on Tygon tubing at various distances to measure forward- and backward-scattered light. Fresh bovine blood (Hct: 30-50%) was circulated in the tubing by a nonpulsatile artificial heart. We calculated the optical path length at various emitter-detector distances by fitting the measured optical outputs and the reference Hcts to Twersky's theory. Then, we performed Hct measurements. As a result, Twersky's theory is applicable not only to forward- but also to backward-scattered measurements in the physiogical Hct range. In both forward- and backward-scattered measurements, calculated optical path lengths become maximum at the same emitter-detector distance. The accuracy of Hct measurement is improved two to three times with the emitter-detector distance compared with other distances. The mean error is less than 1 Hct%. This result shows that an accurate Hct measurement is realized by selecting the optimal emitter-detector distance, which provides maximum optical path length defined by Twersky's theory. Our study provides a framework for the practical and less restrictive application of the optical Hct measurement to patients with an artificial heart.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-1594.2009.00891.xDOI Listing

Publication Analysis

Top Keywords

optical path
20
hct measurement
20
path length
16
artificial heart
16
twersky's theory
16
emitter-detector distance
16
optical
12
backward-scattered measurements
12
forward- backward-scattered
12
measurement
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!