A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Operando X-ray absorption spectroscopy studies on Pd-SnO2 based sensors. | LitMetric

Operando X-ray absorption spectroscopy studies on Pd-SnO2 based sensors.

Phys Chem Chem Phys

Department of Materials, ETH Zürich, Wolfgang Pauli-Strasse, 10, CH-8093, Switzerland.

Published: October 2009

SnO2 gas sensors with palladium as additive in the range of 0.2 wt% and 3 wt% were studied by in situ X-ray absorption spectroscopy under idealized and real operating conditions. Simultaneously to the structural studies, measurements of the sensing properties were undertaken allowing for the determination of structure-function relationships. For this purpose a new in situ spectroscopic cell was designed which permitted on the one hand sensing on conventional screen printed 50 microm thick sensing layers and on the other hand structural analysis with X-rays provided by an insertion device at a 3rd generation synchrotron facility in fluorescence mode. Pd K-edge XANES and EXAFS results on gas sensors showed that palladium, present in an oxidized state, is finely dispersed if it is added in small quantities (0.2 wt%) while it forms clusters at higher concentrations (3 wt%). This is also reflected by the much easier reduction of palladium in the latter, higher concentrated ones. Under realistic sensing conditions (30-200 ppm H2; 10-50 ppm CO in dry and humid air at 200 and 300 degrees C) for the low additive concentration samples, no change in oxidation state was observed, i.e. palladium remained in its oxidized state. This has important consequences on the understanding and modeling of the gas sensing mechanism.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b906829eDOI Listing

Publication Analysis

Top Keywords

x-ray absorption
8
absorption spectroscopy
8
gas sensors
8
sensors palladium
8
oxidized state
8
sensing
5
operando x-ray
4
spectroscopy studies
4
studies pd-sno2
4
pd-sno2 based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!