2-Hydroxypyridine photolytic degradation by 254 nm UV irradiation at different conditions.

Chemosphere

Chemical Engineering, IPSE, School of Process Environmental and Materials Engineering, University of Leeds, Leeds LS2 9JT, UK.

Published: November 2009

The degradation and mineralisation of (400 mL, 3.15 mM) aqueous solutions of 2-hydroxypyridine (2-HPY), a primary intermediate formed during the photolytic degradation of 2-chloropyridine (2-CPY), 2-bromopyridine (2-BPY) and 2-iodopyridine (2-IPY), was studied at 50 degrees C, under 254 nm UV irradiation in a range of conditions. The rate of 2-HPY disappearance was found to heavily depend on agitation, dissolved oxygen, pH and hydroxyl radical scavenger presence. pH has a pronounced effect on the phototreatment of 2-HPY, i.e. 2-HPY removal is faster at lower pH, but except for their influence on the solution pH, Cl(-) or F(-) do not appear to affect 2-HPY rate of removal or mineralisation. 2-HPY removal rate increases with dissolved oxygen, thus indicating a prominent 2-HPY photooxidation pathway. Helium purging of the solution before and during the measurement reduced 2-HPY removal rate, thus supporting the existence of a photooxidation pathway. Pure photolytic 2-HPY removal, i.e. when photooxidation is limited, fits pseudo-first order kinetics, and a kinetic model was developed for 2-HPY formation and removal during 2-CPY, 2-BPY and 2-IPY photolytic degradation under laminar flow. The addition of radical scavenger (tert-butanol) had a detrimental effect on the photolytic degradation of 2-HPY. Complete total organic carbon removal was achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2009.08.026DOI Listing

Publication Analysis

Top Keywords

photolytic degradation
16
2-hpy removal
16
2-hpy
11
254 irradiation
8
dissolved oxygen
8
radical scavenger
8
removal rate
8
photooxidation pathway
8
removal
7
degradation
5

Similar Publications

Background/objectives: Janus kinase inhibitors open new horizons for small-molecule drugs in treating inflammatory bowel disease, with ritlecitinib demonstrating significant efficacy in clinical trials for ulcerative colitis and Crohn's disease. Ritlecitinib, a second-generation JAK3 inhibitor, is a novel therapeutic agent for alopecia areata and other autoimmune conditions.

Methods: A new stability-indicating UHPLC-DAD-MS/MS method was developed, validated, and applied for a forced degradation study of ritlecitinib under ICH guidelines.

View Article and Find Full Text PDF

In this study, a new reversed phase high performance liquid chromatography method using two detectors was developed for the analysis of degradation and process impurities of ivabradine in pharmaceutical preparations. A PDA detector set to 285 nm wavelength and a QDa detector set to positive scan mode were used in the method. In the developed method, the separation process was carried out in a Zorbax phenyl column with a gradient application of a 0.

View Article and Find Full Text PDF

Characterization of main degradation products from dendrobine under stress conditions by multistage cleavage of UPLC-ESI-IT-TOF.

J Pharm Biomed Anal

March 2025

Department of Pharmaceutical Analysis, School of Pharmacy, Guizhou Medical University, Gui'an New District, Guizhou 561113, PR China. Electronic address:

Dendrobine is a sesquiterpene alkaloid primarily used in the treatment of inflammatory diseases, immune system disorders, and conditions related to oxidative stress. To understand the possible degradation pathways of dendrobine for its quality control, we conducted an in-depth investigation of its degradation products using forced degradation methods. The separation of dendrobine and its degradation products was achieved on a Shim-pack XR-ODS III (75 mm × 2 mm, 1.

View Article and Find Full Text PDF
Article Synopsis
  • A stability-indicating HPLC-DAD method was developed to quantify haloperidol in oral solutions using an analytical quality-by-design approach, focusing on key method parameters and material attributes.
  • Haloperidol showed significant degradation under acidic and alkaline conditions, prompting optimization of continuous critical method parameters like flow rate, column temperature, and mobile phase pH.
  • The validated method demonstrated selectivity, accuracy, and precision, establishing normal operating conditions that enhance reliability in stability monitoring of haloperidol.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!