Exposure assessment of kneeling work activities among floor layers.

Appl Ergon

Department of Occupational Medicine, Regional Hospital Skive, Denmark.

Published: March 2010

The objective of this study was to quantify the proportion of kneeling work activities among floor layers and to assess external knee joint forces in five different kneeling work positions. Thirty-three floor layers were videotaped discontinuously and four floor layers were videotaped continuously for a whole working day. External knee forces were measured in five different kneeling work positions in ten floor layers using Computer Dynography. The study showed that floor layers spent a high percentage of time in knee-straining work positions. Kneeling work tasks, particularly gluing and crawling caused high external knee forces ranging from 0.3 Newton (SD 0.2) times body weight when floor layers were kneeling back on the heels, to 3.5 Newton (SD 0.3) times body weight in the crawling work position. The study highlights the need for prevention by minimizing the amount of kneeling work positions among floor layers.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apergo.2009.08.004DOI Listing

Publication Analysis

Top Keywords

floor layers
32
kneeling work
24
work positions
16
external knee
12
work
8
work activities
8
floor
8
activities floor
8
layers
8
layers videotaped
8

Similar Publications

This paper focuses on the theoretical and analytical modeling of a novel seismic isolator termed the Passive Friction Mechanical Metamaterial Seismic Isolator (PFSMBI) system, which is designed for seismic hazard mitigation in multi-story buildings. The PFSMBI system consists of a lattice structure composed of a series of identical small cells interconnected by layers made of viscoelastic materials. The main function of the lattice is to shift the fundamental natural frequency of the building away from the dominant frequency of earthquake excitations by creating low-frequency bandgaps (FBGs) below 20 Hz.

View Article and Find Full Text PDF

Introduction And Hypothesis: The urethra is surrounded by layers of smooth muscle, including inner longitudinal and outer circler muscles, as well as the skeletal muscle of the external urethral sphincter. However, the extent of these muscles and their relationship with the levator ani (LA) remain unclear. This study aimed to clarify the composition of muscle layers around the female urethra and their three-dimensional arrangements.

View Article and Find Full Text PDF

-Loaded Easily Injectable Hydrogel Promotes Endometrial Repair via Long-Term Retention and Microenvironment Modulation.

ACS Nano

January 2025

Guangdong Provincial Key Laboratory of Reproductive Medicine, Guangdong Provincial Clinical Research Center for Obstetrical and Gynecological Diseases, Department of Gynecology & Obstetrics, Reproductive Medicine Center, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou 510080, PR China.

Regeneration of the injured endometrium, particularly the functional layer, is crucial for the prevention of uterine infertility. At present, clinical treatment using sodium hyaluronate hydrogel injection is limited by its relatively low fluidity, short-term retention, and insufficient bioactive ingredients, so it is necessary to develop an advanced healing-promoting hydrogel. The modulation of the microenvironment by presents a bioactive component that can facilitate the regeneration of the functional layer.

View Article and Find Full Text PDF

Objectives: To investigate the outcomes of central cystocele and rectocele repair using natural tissue layers. To describe a novel technique (Dogan technique).

Material And Methods: This is a retrospective cohort study.

View Article and Find Full Text PDF

Purpose: To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).

Methods: UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!