A distal fluted, proximal modular femoral prosthesis in revision hip arthroplasty.

J Arthroplasty

The Department of Orthopedic Surgery of Research Institute of Clinical Medicine, Chonbuk National University, Jeonju, Korea.

Published: September 2010

Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, 4 had a displaced greater trochanter. Re-revision was performed in 5 patients, and 3 of these were for subsidence (of these 3, subsidence was associated with dissociation of the coupling part in 1 and with osteotomy nonunion in other 2 [proximal component only]). Modular distally fixed femoral stems were found to offer intraoperative flexibility, but to suffer from subsidence and intraoperative greater trochanter and metaphyseal femoral fractures.