Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: The aim of the Titan PORI Registry was to evaluate the safety and efficacy of a stainless steel stent coated with titanium nitride oxide (Titan(R), Hexacath, France) in routine clinical practice.
Methods And Results: We report a prospective single-centre experience in treating patients with the Titan(R) stent. All consecutive patients receiving Titan(R) stent(s) were enrolled. The choice of a stent was at the discretion of the operator with no exclusion criteria. The primary end point of the registry was Major Adverse Cardiac Events (MACE) at 6 and 9 months. A total of 210 lesions were treated in 193 enrolled patients (mean age 67+/-10; men 71%; diabetes 17%). Lesions were of type B in 64% and type C in 23%. The indications for PCI were unstable angina or non-Q-wave MI in 36% and acute STEMI in 30% of the patients. Mean reference diameter was 2.9+/-0.3 mm and mean lesion length 12.9+/-3.0 mm. Mean stent size was 2.98 mm (range 2-3.5 mm) and length 15.5 mm (range 7-28 mm). Stent delivery was successful in all cases (23% direct stenting). Complete follow-up of all 193 patients was obtained up to 9 months. There were no in-hospital or 30-day MACE observed. At 270 days, the MACE rate was 10.4% (MI 4.1%, cardiac death 0%, TVR 8.3%). There were no cases with stent thrombosis.
Conclusion: These medium term data confirm good safety profile of Titan(R) stent even in high risk patients and complex coronary lesions in routine clinical use.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!