Background: Previous studies of multidetector CT (MDCT) of the lower extremities for the detection of peripheral vascular disease showed high diagnostic accuracy but were performed with older generation systems.

Objective: The purpose of this study was to evaluate the diagnostic accuracy of 64 MDCT for the detection of hemodynamically significant disease within the lower extremity peripheral vasculature as compared to digital subtraction angiography (DSA).

Methods: Twenty-eight consecutive patients with symptomatic lower extremity intermittent claudication and an abnormal ankle-brachial index (ABI; less than 0.9) were evaluated by both 64 MDCT and DSA. Axial images were acquired with a 64 multidetector general electric light speed VCT scanner. Images were analyzed using a GE Advantage workstation (AW 4.3) capable of advanced image processing and manipulation. The aorto-iliac and lower extremity arteries were divided into 15 segments per limb (30 segments per patient). Eight hundred forty segments were analyzed in a blinded fashion by physicians with level III CT certification. Segments were classified as grade I (<10% stenosis), grade II (10-49%), grade III (50-99%), and grade IV (occlusion).

Results: For all segments evaluated, the overall diagnostic accuracy for detecting grade III and IV lesions was 98% with a sensitivity of 99% and a specificity of 98%. For the aorto-iliac segments, the diagnostic accuracy was 98% with a sensitivity of 100% and a specificity of 99%. For the femoro-popliteal segments, the overall accuracy was 98% with a sensitivity of 100% and a specificity of 99%. For the infra-popliteal segments, the overall accuracy was 98% with a sensitivity of 97% and a specificity of 99%. One segment could not be visualized by MDCT compared to 49 segments that could not be visualized by DSA.

Conclusions: This study demonstrates excellent diagnostic accuracy of 64 MDCT in the detection of hemodynamically significant disease of the lower extremities. More segments are visualized using 64 MDCT than DSA, allowing more complete visualization of the vascular tree. CT angiography should be considered in the diagnostic evaluation of symptomatic patients with peripheral vascular disease.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ccd.22228DOI Listing

Publication Analysis

Top Keywords

diagnostic accuracy
12
lower extremity
12
peripheral vascular
8
vascular disease
8
accuracy multidetector
4
multidetector computed
4
computed tomographic
4
tomographic angiography
4
angiography peripheral
4
disease background
4

Similar Publications

Simultaneous and Ultraspecific Optical Detection of Multiple miRNAs Using a Liquid Flow-Based Microfluidic Assay.

ACS Appl Mater Interfaces

January 2025

Department of Chemistry, Yeungnam University, 280 Daehak-ro, Gyeongsan-si, Gyeongsangbuk-do 38541, Republic of Korea.

Recent studies have reported that the cause and progression of many diseases are closely related to complex and diverse gene regulation involving multiple microRNAs (miRNAs). However, most existing methods for miRNA detection typically deal with one sample at a time, which limits the achievement of high diagnostic accuracy for diseases associated with multiple gene dysregulations. Herein, we develop a liquid flow-based microfluidic optical assay for the simple and reliable detection of two different target miRNAs simultaneously at room temperature without any enzymatic reactions.

View Article and Find Full Text PDF

ECG Patterns of Occlusion Myocardial Infarction: A Narrative Review.

Ann Emerg Med

January 2025

Department of Emergency Medicine, University of Minnesota, Minneapolis, MN; Department of Emergency Medicine, Hennepin Healthcare, Minneapolis, MN.

The traditional management of acute coronary syndrome has relied on the identification of ST-segment elevation myocardial infarction (STEMI) as a proxy of acute coronary occlusion. This conflation of STEMI with acute coronary occlusion has historically overshadowed non-ST-segment elevation myocardial infarction (NSTEMI), despite evidence suggesting 25% to 34% of NSTEMI cases may also include acute coronary occlusion. Current limitations in the STEMI/NSTEMI binary framework underscore the need for a revised approach to chest pain and acute coronary syndrome management.

View Article and Find Full Text PDF

Ultrasound-guided intercostal nerve injection in rabbit cadavers: Technique description and comparison with blind approach.

Vet Anaesth Analg

December 2024

Department of Comparative Diagnostic, and Population Medicine, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA. Electronic address:

Objective: To develop an ultrasound-guided technique for intercostal nerve blocks in rabbit cadavers and to compare the success rate and potential complications of this technique to blind injection.

Study Design: Prospective, randomized, blinded, descriptive experimental cadaveric study.

Animals: A group of nine adult domestic rabbit cadavers (body mass 1.

View Article and Find Full Text PDF

To evaluate the clinical value of multi-slice spiral CT in preoperative TNN staging and postoperative recurrence and metastasis of colon carcinoma, and to provide evidence for the reliability of CT in the diagnosis of colon carcinoma METHODS: 89 patients with colon carcinoma diagnosed pathologically in our hospital from July 2020 to April 2023 were selected retrospectively. The preoperative TNN staging and postoperative recurrence and metastasis were monitored by 64 row 128 layer spiral CT. The diagnostic coincidence rate, TNM staging coincidence rate and postoperative recurrent TNM staging accuracy were evaluated according to the pathological diagnosis RESULTS: The diagnostic coincidence rate of multi-slice spiral CT was 97.

View Article and Find Full Text PDF

Evaluation of a next generation sequencing assay for Hepatitis B antiviral drug resistance on the oxford nanopore system.

J Clin Virol

January 2025

Division of Medical Microbiology and Virology, St. Paul's Hospital, Providence Health Care, Vancouver, British Columbia, Canada; Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada. Electronic address:

Background: Next-generation sequencing (NGS) for Hepatitis B virus (HBV) antiviral resistance (AVR) testing is a highly sensitive diagnostic method, able to detect low-level mutant subpopulations. Our clinical virology laboratory previously transitioned from DNA hybridization (INNO-LiPA) to NGS, initially with the GS Junior System and subsequently the MiSeq. The Oxford Nanopore Technology (ONT) sequencing system was evaluated for HBV resistance testing, with regards to sequencing accuracy and turn-around time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!