Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood.

Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper method was assessed by comparing HbA1c results from EDTA-blood samples obtained via dried blood spots with HbA1c results obtained with freshly hemolyzed blood (routine HbA1c). Adult patients visiting the outpatient clinic for HbA1c analyses were recruited for the evaluation of dried blood spot sampling at home. Laboratory personnel collected a capillary blood sample on filter paper as well as a venous EDTA-blood sample. The participants collected another capillary blood sample at home and sent the dried filter paper back to the laboratory. Samples were analyzed with an immunoturbidimetric assay.

Results: Between-filter coefficient of variation was 1.8%. Filter paper HbA1c increased slightly during storage, particularly during the first 5 days. Filter paper HbA1c highly correlated with routine HbA1c (r=0.987). The evaluation of samples collected at home showed comparable HbA1c values by filter paper and routine sampling methods (n=93). Eighty-three percent of participants said they would like the filter method to be brought into practice.

Conclusions: Home HbA1c sampling on filter paper is an acceptable sampling alternative for analysis of HbA1c.

Download full-text PDF

Source
http://dx.doi.org/10.1515/CCLM.2009.274DOI Listing

Publication Analysis

Top Keywords

filter paper
36
dried blood
16
hba1c
14
blood spots
12
capillary blood
12
filter
10
paper
9
hba1c measurements
8
measurements dried
8
blood
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!