Reconstruction of humeral head defect for locked posterior shoulder dislocation.

Orthopedics

Heart of England NHS Foundation Trust, 23 Harts Green Road, Harborne, Birmingham, West Midlands, United Kingdom.

Published: September 2009

Locked posterior shoulder dislocation is a rare injury and is often missed on examination, usually due to inadequate imaging and potentially resulting in significant loss of shoulder function. An important feature of the physical examination is identification of the patient's inability to externally rotate their arm. These injuries are associated with defects in the humeral head articular surface, also known as reverse Hill-Sachs lesions. Medium-sized defects involving 25% to 50% of the articular surface can be reconstructed using several methods, including subscapularis or lesser tuberosity transfer, rotational osteotomy of the humerus, osteochondral autografting, and allograft reconstruction. We describe reconstruction of a 40% anteromedial humeral head articular surface defect associated with a missed locked posterior shoulder dislocation. Our technique used a deltopectoral approach with soft tissue dissection through the rotator interval to enable direct access to the defect with preservation of the rotator cuff muscles. The impacted articular surface was elevated, and the void was filled with moldable putty consisting of tricalcium phosphate with carboxymethylcellulose (Calstrux; Stryker Biotech, Hopkinton, Massachusetts). The articular fragment was then secured in position with size 5 Ethibond (Ethicon, Inc, Somerville, New Jersey) bone sutures. The patient regained excellent function and range of motion, with computed tomography scanning at 9 months demonstrating a smooth humeral articular surface with excellent graft incorporation. This technique avoids donor site morbidity and potential risks with allograft use while maintaining normal shoulder joint anatomy with preservation of the rotator cuff muscles for less complicated prosthetic reconstruction if required in the future.

Download full-text PDF

Source
http://dx.doi.org/10.3928/01477447-20090728-43DOI Listing

Publication Analysis

Top Keywords

articular surface
20
humeral head
12
locked posterior
12
posterior shoulder
12
shoulder dislocation
12
head articular
8
preservation rotator
8
rotator cuff
8
cuff muscles
8
articular
6

Similar Publications

Gibbons, a type of lesser ape, are brachiators but also walk bipedally and without forelimb assistance, not only on the ground but also on tree branches. The arboreal bipedal walking strategy of the gibbons has been studied in previous studies in relation to two-dimensional (2D) kinematic analysis. However, because tree branches and the ground differ greatly in width, leading to a constrained foot contact point on the tree branches, gibbons must adjust their 3D joint motions of trunk and hindlimb on the tree branches.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Introduction The role of the condylar position in the correct functioning of the stomatognathic system has been the center of the study. Using cone-beam computed tomography (CBCT), this study looked at the three-dimensional (3D) position of the condylar bone in patients from Class I, Class II, Division 1, and Division 2. Materials and methods This cross-sectional, retrospective study was conducted using 102 CBCT records, with 34 records allocated to each category of malocclusion classification, such as dentoskeletal Class I, skeletal Class II, and dental Class II, Division 1 and 2.

View Article and Find Full Text PDF

Enhanced bone cement for fixation of prosthetic joint utilizing nanoparticles.

J Mater Sci Mater Med

January 2025

Biomedical Engineering Department, Faculty of Engineering, Helwan University, Cairo, Egypt.

Bone cement is commonly utilized to secure prosthetic joints in the body because of its robust fixation, stability, biocompatibility, and immediate load-bearing capability. However, issues such as loosening, leakage, and insufficient bioactivity can lead to its failure. Therefore, improving its mechanical, physical, and biological properties is crucial for enhancing its efficiency.

View Article and Find Full Text PDF

Background: To explore the advantages of a lateral tibial locking plate combined with Jail screw fixation in the treatment of anterolateral tibial plateau collapse fracture (ATPCF).

Methods: A retrospective analysis was conducted on patients with ATPCFs admitted to our hospital from February 2019 to February 2023. Twenty-six patients were successfully included, including 15 males and 11 females, with an average age of 58.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!