Aim: To evaluate whether computer-aided detection (CAD) as a second reader using perspective filet view [three-dimensional (3D) filet] improves the performance of inexperienced readers at computed tomography colonography (CTC) compared with unassisted 3D filet and unassisted two-dimensional (2D) CTC.
Material And Methods: Fifty symptomatic patients underwent CTC and same-day colonoscopy with segmental unblinding. Two inexperienced readers read the CTC studies on 3D filet and 2D several weeks apart. Four months later, readers re-read the cases only evaluating CAD marks using 3D filet. Suspicious CAD marks not previously described on 3D filet were recorded. Jackknife free-response receiver operating characteristic (JAFROC-1) analysis was used to compare the observers' performances in detecting lesions with 3D filet, 2D and 3D filet with CAD.
Results: One hundred and three lesions > or =3mm were detected at colonoscopy with segmental unblinding. CAD alone had a sensitivity of 73% (75/103) at a mean false-positive rate per patient of 12.8 in supine and 11.4 in prone. For inexperienced readers sensitivities with 3D filet with CAD were 58% (60/103) and 48% (50/103) with an improvement of 14-16 percentage points (p<0.05) compared with 2D and of 10-11 percentage points (p<0.05) compared with 3D filet. For inexperienced readers, the false-positive rate was 25-41% and 71-200% higher with 3D filet with CAD compared with 3D filet and 2D, respectively. JAFROC-1 analysis showed no significant differences in per-lesion overall performance among reading modes (p=0.8).
Conclusion: CAD applied as a second reader using 3D filet increased both sensitivity and the number of false positives by inexperienced readers compared with 3D filet and 2D, thus not improving overall performance, i.e., the ability to distinguish between lesions and non-lesions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.crad.2009.05.012 | DOI Listing |
Rofo
November 2024
Klinikum Lippe, Department of Diagnostic and Interventional Radiology, Bielefeld University, Medical School and University Medical Center OWL, Detmold, Germany.
Contrast-enhanced CT is the standard imaging technique in oncological objectives. Rates of missed pathologies depend on work experience of the respective radiologists. Thus the aim of this study is to analyze the eye movements of professionals while reading CT images in order to evaluate whether the eye-fixation patterns and search strategies of experienced radiologists could explain higher detection rates of pathologies and whether such patterns can be learned.
View Article and Find Full Text PDFScand J Prim Health Care
September 2024
Research and Development Unit in Region Östergötland, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
Young adults experiencing unfamiliar symptoms commonly seek health information online. This study's aim was to explore how health information websites express and communicate health information about symptoms common among young adults and guide readers in regard to health, illness, and care. Symptoms commonly searched for by young adults were used as search terms.
View Article and Find Full Text PDFBackground: In spinal revision surgery, previous pedicle screws (PS) may need to be replaced with new implants. Failure to accurately identify the brand of PS-based instrumentation preoperatively may increase the risk of perioperative complications. This study aimed to develop and validate an optimal deep learning (DL) model to identify the brand of PS-based instrumentation on plain radiographs of spine (PRS) using anteroposterior (AP) and lateral images.
View Article and Find Full Text PDFFront Endocrinol (Lausanne)
September 2024
Department of Radiology, College of Medicine, Yonsei University, Seoul, Republic of Korea.
[This corrects the article DOI: 10.3389/fendo.2024.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!