The Calypso Medical 4D localization system utilizes alternating current electromagnetics for accurate, real-time tumor tracking. A quality assurance program to clinically implement this system is described here. Testing of the continuous electromagnetic tracking system (Calypso Medical Technologies, Seattle, WA) was performed using an in-house developed four-dimensional stage and a quality assurance fixture containing three radiofrequency transponders at independently measured locations. The following tests were performed to validate the Calypso system: (a) Localization and tracking accuracy, (b) system reproducibility, (c) measurement of the latency of the tracking system, and (d) measurement of transmission through the Calypso table overlay and the electromagnetic array. The translational and rotational localization accuracies were found to be within 0.01 cm and 1.0 degree, respectively. The reproducibility was within 0.1 cm. The average system latency was measured to be within 303 ms. The attenuation by the Calypso overlay was measured to be 1.0% for both 6 and 18 MV photons. The attenuations by the Calypso array were measured to be 2% and 1.5% for 6 and 18 MV photons, respectively. For oblique angles, the transmission was measured to be 3% for 6 MV, while it was 2% for 18 MV photons. A quality assurance process has been developed for the clinical implementation of an electromagnetic tracking system in radiation therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.3158812DOI Listing

Publication Analysis

Top Keywords

quality assurance
16
tracking system
16
electromagnetic tracking
12
system
9
clinical implementation
8
implementation electromagnetic
8
system calypso
8
calypso medical
8
tracking
6
calypso
6

Similar Publications

Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.

Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.

View Article and Find Full Text PDF

Behind the scenes of EQA-characteristics, capabilities, benefits and assets of external quality assessment (EQA).

Clin Chem Lab Med

January 2025

Canadian Microbiology Proficiency Testing Program (CMPT), Department of Pathology and Laboratory Medicine, University of British Columbia, Vancouver, Canada.

The main stakeholders in external quality assessment (EQA) programs are the participants, in whose interests these challenges are ultimately organised. EQA schemes in the medical field contribute to improving the quality of patient care by evaluating the analytical and diagnostic quality of laboratory and point-of-care tests (POCT) by independent third parties and, if necessary, pointing out erroneous measurement results and analytical or diagnostic improvement potential. Other benefits include the option of using EQA samples for other important laboratory procedures, such as the verification or validation of diagnostic medical devices (IVD-MDs), a contribution to the estimation of measurement uncertainty, a means of training and educating laboratory staff through educational EQA programmes or samples, or even for independent and documented monitoring of staff competence, such as on samples with unusual or even exceptional characteristics.

View Article and Find Full Text PDF

We extend existing techniques by using generative adversarial network (GAN) models to reduce the appearance of cast shadows in radiographs across various age groups. We retrospectively collected 11,500 adult and paediatric wrist radiographs, evenly divided between those with and without casts. The test subset consisted of 750 radiographs with cast and 750 without cast.

View Article and Find Full Text PDF

For commercial viability, cultivated meats require scientifically informed approaches to identify and manage hazards and risks. Here we discuss food safety in the rapidly developing field of cultivated meat as it shifts from lab-based to commercial scales. We focus on what science-informed risk mitigation processes can be implemented from neighbouring fields.

View Article and Find Full Text PDF

Behind the scenes of EQA - characteristics, capabilities, benefits and assets of external quality assessment (EQA).

Clin Chem Lab Med

January 2025

Department of Pathology and Laboratory Medicine, Canadian Microbiology Proficiency Testing Program (CMPT), University of British Columbia, Vancouver, Canada.

This is the first in a series of five papers that detail the role and substantial impact that external quality assessment (EQA) and their providers' services play in ensuring diagnostic (IVD) performance quality. The aim is to give readers and users of EQA services an insight into the processes in EQA, explain to them what happens before EQA samples are delivered and after examination results are submitted to the provider, how they are assessed, what benefits participants can expect, but also who are stakeholders other than participants and what significance do EQA data and assessment results have for them. This first paper presents the history of EQA, insights into legal, financing and ethical matters, information technology used in EQA, structure and lifecycle of EQA programs, frequency and intensity of challenges, and unique requirements of extra-examination and educational EQA programs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!