We describe a methodology to quantify and separate the errors of inherent optical properties (IOPs) derived from ocean-color model inversion. Their total error is decomposed into three different sources, namely, model approximations and inversion, sensor noise, and atmospheric correction. Prior information on plausible ranges of observation, sensor noise, and inversion goodness-of-fit are employed to derive the posterior probability distribution of the IOPs. The relative contribution of each error component to the total error budget of the IOPs, all being of stochastic nature, is then quantified. The method is validated with the International Ocean Colour Coordinating Group (IOCCG) data set and the NASA bio-Optical Marine Algorithm Data set (NOMAD). The derived errors are close to the known values with correlation coefficients of 60-90% and 67-90% for IOCCG and NOMAD data sets, respectively. Model-induced errors inherent to the derived IOPs are between 10% and 57% of the total error, whereas atmospheric-induced errors are in general above 43% and up to 90% for both data sets. The proposed method is applied to synthesized and in situ measured populations of IOPs. The mean relative errors of the derived values are between 2% and 20%. A specific error table to the Medium Resolution Imaging Spectrometer (MERIS) sensor is constructed. It serves as a benchmark to evaluate the performance of the atmospheric correction method and to compute atmospheric-induced errors. Our method has a better performance and is more appropriate to estimate actual errors of ocean-color derived products than the previously suggested methods. Moreover, it is generic and can be applied to quantify the error of any derived biogeophysical parameter regardless of the used derivation.

Download full-text PDF

Source
http://dx.doi.org/10.1364/AO.48.004947DOI Listing

Publication Analysis

Top Keywords

total error
12
inherent optical
8
optical properties
8
errors inherent
8
sensor noise
8
atmospheric correction
8
iops relative
8
data set
8
data sets
8
atmospheric-induced errors
8

Similar Publications

Clinical Relevance: When selecting an intervention for myopia management, parental inquiries centre around the comparative efficacy of orthokeratology versus myopic defocus spectacle lenses. This prompts an intriguing investigation into the nuanced differences between these two treatment methods.

Background: This study aimed to compare the efficacy of spectacle lenses with highly aspherical lenslets (HAL) versus orthokeratology (Ortho-k) in controlling axial length elongation.

View Article and Find Full Text PDF

Validating the accuracy of mathematical model-based pharmacogenomics dose prediction with real-world data.

Eur J Clin Pharmacol

January 2025

Electrical and Computer Engineering Department, School of Engineering, Lebanese American University, P.O. Box: 36, Byblos, F-19, Lebanon.

Objective: The study aims to verify the usage of mathematical modeling in predicting patients' medication doses in association with their genotypes versus real-world data.

Methods: The work relied on collecting, extracting, and using real-world data on dosing and patients' genotypes. Drug metabolizing enzymes, i.

View Article and Find Full Text PDF

Background And Aims: Population aging is associated with the rising incidence of chronic illness. This presents a significant challenge to healthcare systems, particularly in developing countries, as untreated chronic conditions can lead to years of disability and loss of independence straining health budgets and resources. Promoting healthy aging can be one avenue for mitigating these challenges.

View Article and Find Full Text PDF

Background: Antibiotics are widely used medications among infectious disease patients; therefore, proper monitoring and assessment are critical for ensuring rational use. Antimicrobial stewardship addresses the rational and appropriate use of antibiotics, which reinforces overall health outcomes. Ongoing antimicrobial resistance scenarios are an alarming condition for healthcare, necessitating continued practice of such assessments.

View Article and Find Full Text PDF

Background: Accurate assessment of oxygen delivery relative to oxygen demand is crucial in the care of a critically ill patient. The central venous oxygen saturation (Svo) enables an estimate of cardiac output yet obtaining these clinical data requires invasive procedures and repeated blood sampling. Interpretation remains subjective and vulnerable to error.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!