Technological developments of multiparametric flow cytometry come along with the generation of new dyes. The APC-tandem dyes, which combine the fluorophores APC and Cy7/H7, allow the detection of a specific signal in the APC-Cy7/H7 channel along with an unexpected nonspecific signal in the APC channel. Depending on the magnitude of the latter, it may be a handicap for interpreting the data of multicolor labeling experiments. We investigated the alteration of the APC-tandem dyes by labeling peripheral blood cells with antibodies directed toward leukocyte surface proteins and by analyzing cells by flow cytometry. Our results show that the APC-Cy7/H7 tandem fluorochromes degraded over time. Nonspecific APC signal was observed with the various antibodies tested only upon cell attachment but not under bead linkage. Moreover, the percentage of degradation of the APC-Cy7/H7 dyes was dependent on the cell type analyzed. Interestingly, nonspecific APC signal strongly decreased when the metabolic activity of immunolabeled cells was inhibited or when cells were incubated with vitamin C. This study demonstrates that the APC-tandem dyes are the target of cell-dependent degradation, which may be antagonized. These findings will allow cytometer users to optimize their multicolor panels.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cyto.a.20774DOI Listing

Publication Analysis

Top Keywords

apc-tandem dyes
16
flow cytometry
12
nonspecific apc
8
apc signal
8
dyes
6
apc-tandem
4
cytometry apc-tandem
4
dyes degraded
4
degraded cell-dependent
4
cell-dependent mechanism
4

Similar Publications

Technological developments of multiparametric flow cytometry come along with the generation of new dyes. The APC-tandem dyes, which combine the fluorophores APC and Cy7/H7, allow the detection of a specific signal in the APC-Cy7/H7 channel along with an unexpected nonspecific signal in the APC channel. Depending on the magnitude of the latter, it may be a handicap for interpreting the data of multicolor labeling experiments.

View Article and Find Full Text PDF

We demonstrate the utility of indotricarbocyanine (Cy7) conjugates of the phycobiliproteins phycoerythrin (PE) and allophycocyanin (APC) in flow cytometry. This is the first demonstration of the use of an APC tandem dye for fluorescence measurements. These resonance energy transfer tandem dyes can be excited by the phycobiliprotein-specific excitation wavelengths and fluoresce at wavelengths above 780 nm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!