Intramucosal inserts made of zirconia ceramic have been used for the rehabilitation of edentulous patients. This study aimed to follow up on patients with complete dentures having intramucosal zirconia inserts and to perform a histological analysis of biopsies of the epithelium surrounding the inserts. Twelve 31-66-year-old subjects of both genders received complete denture treatment having the intramucosal inserts in place. Detailed clinical, prosthetic and surgical procedures were described. Clinical exams were done on postoperative days 3, 7, 15, 120 and 360. One year after denture placement, the subjects received local anesthesia and the tissues surrounding the insertion sites in the alveolar ridge were removed using a scalpel blade. Biopsies were fixed for up to 48 h in 10% phosphate-buffered formaldehyde and 5-microm-thick sections were cut and stained with hematoxylin and eosin and Gomori Trichrome. Immunohistochemistry was used to identify endothelium (anti-CD3) and T lymphocytes (anti-CD31). Removing and reinserting the denture was painful until day 15, but all patients reported a marked increase in the retention and stability of the complete denture with little or no discomfort after 30 days. The histopathological analysis showed that zirconia inserts were well tolerated by the oral mucosa, with the presence of collagen fibers in the tissue around the insert, with mild inflammatory response and allowing reepithelialization, expressed by parakeratosis, epithelial hyperplasia and presenting granular layer. In conclusion, intramucosal zirconia inserts did not affect the health of oral mucosa and provide adequate retention and stability of the complete denture and comfort to the patients.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402009000200011DOI Listing

Publication Analysis

Top Keywords

zirconia inserts
16
intramucosal zirconia
12
complete denture
12
histopathological analysis
8
intramucosal inserts
8
retention stability
8
stability complete
8
oral mucosa
8
inserts
7
denture
6

Similar Publications

Introduction: Bone remodeling around implants in implant-supported rehabilitation is a continuous debate with no consensus in the literature. This study aimed to investigate the implant- and patient-specific factors contributing to marginal bone loss near the implant.

Materials And Methods: We included patients who had implant-supported prosthetic rehabilitation using one implant system, between 2014 and 2018, who had full follow-up documentation and orthopantomography over five years, and who had no unwell-controlled systemic pathologies that may influence bone metabolism.

View Article and Find Full Text PDF

Objective: To assess the clinical, radiographic and patient-reported outcome measures, and the success of screw-retained one-piece monolithic zirconia implant-supported restorations in the posterior region during a 1-year follow-up.

Methods: In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum age of 18 years and sufficient bone volume for placing an implant (≥ 8 mm) and space for an anatomical restoration were included. Following prosthetic-driven digital three-dimensional treatment planning, a tissue-level implant with an internal connection was inserted during a one-stage surgical procedure.

View Article and Find Full Text PDF

Objectives: Follow-up results of modern zirconia implants inserted in fibula free and deep circumflex iliac artery (DCIA) flaps with fixed dentures are scarce. This study aimed to evaluate crestal bone changes and the survival rate of zirconia implants for up to 1.5 years of prospective follow-up.

View Article and Find Full Text PDF

Objectives: Variations in transmucosal abutment contour design may affect the outcomes of implant therapy. This randomized controlled trial was primarily aimed at testing the effect that CAD/CAM zirconia abutments with either a concave or linear divergent transmucosal morphology have on peri-implant mucosal dynamics and indicators of peri-implant health at 1 year after final implant-supported prosthesis insertion in the anterior maxilla.

Materials And Methods: Following computer-guided implant placement and osseointegration, eligible subjects were randomized into either the experimental (concave morphology) or the control (linear divergent morphology) group.

View Article and Find Full Text PDF

Primary Stability of Zirconia Dental Implants with Cylindrical and Tapered Designs Across Varying Bone Densities: An In Vitro Evaluation.

Dent J (Basel)

November 2024

Department of Oral Surgery and Oral Medicine, Faculdade de Medicina Dentária da Universidade de Lisboa, 1600-277 Lisbon, Portugal.

While titanium implants are widely recognized for their clinical success, zirconia implants have emerged as a metal-free alternative. This study aimed to evaluate the influence of zirconia implant macrogeometry and bone density on primary implant stability. Two types of zirconia implants were tested-the Neodent Zi Ceramic Implant and the Straumann PURE Ceramic Implant, that were placed into polyurethane foam blocks mimicking different bone densities (10 PCF, 15 PCF, 20 PCF, 30 PCF, and 40 PCF).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!