This study evaluated the effect of denture base polymer type (heat- and microwave-polymerized), ridge lap surface treatment (with and without methyl methacrylate-MMA etching) and thermocycling on the microtensile bond strength (microTBS) of Biotone acrylic teeth. Flat-ground, ridge-lap surface of posterior artificial teeth were bonded to cylinders of each denture base resin, resulting in the following groups (n=6): G1a - Clássico/with MMA etching; G1b - Clássico/without MMA etching; G2a - OndaCryl/with MMA etching; G2b - OndaCryl/without MMA etching. Rectangular bar specimens with a cross-sectional area of 1 mm(2) were prepared. Half of the bars in each group were thermocycled (5,000 cycles between 4 degrees C and 60 degrees C). microTBS testing was performed in an universal testing machine at a crosshead speed of 0.5 mm/min. Data were analyzed statistically by three-way ANOVA (alpha=0.05). There was no statistically significant difference (p>0.05) for the factors (resin, surface treatment,and thermocycling) or their interactions. The mean microTBS values (MPa) and standard deviations were as follows: Thermocycling - G1a: 41.00 (14.00); G1b: 31.00 (17.00); G2a: 50.00 (27.00); G2b: 40.00 (18.00); No thermocycling - G1a: 37.00 (14.00); G1b: 43.00 (25.00); G2a: 43.00 (14.00); G2b: 40.00 (27.00). The microTBS of Biotone artificial teeth to the denture base acrylic resins was not influenced by the polymer type, surface treatment or thermocycling.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s0103-64402009000200007DOI Listing

Publication Analysis

Top Keywords

denture base
16
mma etching
16
surface treatment
12
ridge lap
8
lap surface
8
treatment thermocycling
8
thermocycling microtensile
8
microtensile bond
8
bond strength
8
acrylic teeth
8

Similar Publications

Purpose: In this randomized clinical trial, we examined the incorporation of nanogold particles into polymethyl methacrylate denture bases and compared these modified bases with conventional ones in mandibular implant-retained overdentures, focusing on microbiological growth and adhesion characteristics.

Methods: In this study, twenty-two male patients who were completely edentulous participated in a rehabilitation program involving mandibular overdentures retained by two dental implants placed in the canine area. The subjects were categorized into two equal groups, each comprising eleven patients.

View Article and Find Full Text PDF

Purpose: Acrylic dentures fabricated using polymethyl methacrylate are subjected to either intraoral fatigue stress or extraoral impact stress, eventually forming microcracks and fractures. This limitation should be overcome by either modification in the acrylic resin material or in polymerization techniques. This study compares the impact strength and flexural strength of high-impact resin to conventional resin in short- and long-heat polymerization settings.

View Article and Find Full Text PDF

Statement Of Problem: Comprehensive data are needed on the performance of chemically activated, chairside hard reline materials when used with computer-aided design and computer-aided manufacturing (CAD-CAM) milled polymethyl methacrylate (PMMA) denture bases and conventionally processed bases. This lack of data affects decisions regarding the chairside reline material to be used for improving the fit and retention of relined complete dentures.

Purpose: The purpose of this in vitro study was to evaluate and compare the shear bond strength (SBS) of 3 chemically activated, chairside hard reline materials on CAD-CAM milled and conventional heat-polymerized PMMA denture bases.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

CAD-CAM complete digital dentures: An improved clinical and laboratory workflow.

J Prosthet Dent

December 2024

Associate Professor and Department Head, Department of Prosthodontics, University of Ferrara, Ferrara, Italy.

The purpose of this article was to present a novel clinical workflow for the fabrication of complete dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) technology. The dental technique consists of 3 clinical steps and 2 laboratory phases that result in the production of 2 CAD-CAM milled complete denture bases with prefabricated teeth. The integration of analog and digital procedures and materials maximizes their benefits in the planning and fabrication of complete dentures, with the goal of improving clinical outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!