The resolution of cryo-electron tomography can be limited by the first zero of the microscope's contrast transfer function (CTF). To achieve higher resolution, it is critical to determine the CTF and correct its phase inversions. However, the extremely low signal-to-noise ratio (SNR) and the defocus gradient in the projections of tilted specimens make this process challenging. Two programs, CTFPLOTTER and CTFPHASEFLIP, have been developed to address these issues. CTFPLOTTER obtains a 1D power spectrum by periodogram averaging and rotational averaging and it estimates the noise background with a novel approach, which uses images taken with no specimen. The background-subtracted 1D power spectra from image regions at different defocus values are then shifted to align their first zeros and averaged together. This averaging improves the SNR sufficiently that it becomes possible to determine the defocus for subsets of the tilt series rather than just the entire series. CTFPHASEFLIP corrects images line-by-line by inverting phases appropriately in thin strips of the image at nearly constant defocus. CTF correction by these methods is shown to improve the resolution of aligned, averaged particles extracted from tomograms. However, some restoration of Fourier amplitudes at high frequencies is important for seeing the benefits from CTF correction.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784817 | PMC |
http://dx.doi.org/10.1016/j.jsb.2009.08.016 | DOI Listing |
J Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFSTAR Protoc
January 2025
Key Laboratory for Protein Sciences of Ministry of Education, School of Life Sciences, Tsinghua University, Beijing 100084, China; State Key Laboratory of Membrane Biology, School of Life Sciences, Tsinghua University, Beijing 100084, China; Tsinghua-Peking Joint Center for Life Sciences, Beijing 100084, China; Beijing Frontier Research Center for Biological Structure, Beijing 100084, China; School of Life Sciences, Tsinghua University, Beijing 100084, China. Electronic address:
Contrast transfer function (CTF) estimation is essential to the data processing workflow of cryo-electron tomography (cryoET). Here, we present a protocol for CTF estimation of the cryoET tilt series with CTFMeasure. CTFMeasure can estimate the CTF parameters together with the absolute tilt angle offset of the sample.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
January 2025
Orthopaedic Department, Croix St Simon Hospital 125 rue d'Avron, 75020 Paris, France.
Introduction: Spinopelvic kinematics, reflected by the change in spinopelvic tilt (ΔSPT) from a standing position to a flexed seated position, has been associated with the risk of prosthetic impingement and hip dislocation. Some studies have suggested changes in spinopelvic mobility after total hip arthroplasty (THA), but none have explored changes in mobility in the first three months following THA using a direct anterior approach.
Hypothesis: Our hypothesis was that changes in spinopelvic mobility occur in the first 3 months postoperatively, leading to increased hip mobility and increased spinopelvic kinematic abnormalities.
Methods Mol Biol
January 2025
Cambridge Institute for Medical Research (CIMR) and Department of Clinical Biochemistry, University of Cambridge School of Clinical Medicine, Cambridge, UK.
Electron tomography can provide additional morphological information not easily obtained by conventional transmission electron microscopy of thin sections. It uses a goniometer stage in the electron microscope to tilt the specimen and collect a series of 2D images from different orientations, which are combined to provide a 3D volume tomogram and a colored reconstruction of the morphological feature(s) of interest. Here we describe the protocols for its use in visualizing changes in organelle morphology after depletion of the SNARE proteins VAMP7 and VAMP8 and to study VAMP7 localization on endolysosomes/lysosomes.
View Article and Find Full Text PDFSci Rep
January 2025
School of Physics, Ningxia University, Yinchuan, 750021, China.
Optimizing the installation parameters of photovoltaic panels in a photovoltaic array to reduce dust accumulation, thereby enhancing their power generation, is a crucial research topic in the construction of solar power stations in desert regions. Utilizing a series of wind tunnel experiments on a photovoltaic array comprising four equally sized panels, this study assessed how variations in tilt angle, mounting height, spacing, and incoming flow direction influence both the accumulation mass of dust and the particle size distribution in a photovoltaic array. The results indicate that the dust accumulation on the first panel exponential growth with increasing tilt angle, incoming flow angles, and height, while subsequent panels displayed a trend of initial increase followed by a decrease, with a maximum increasing ratio achieved at specific installation configurations, the difference of dust mass on each panel can even be several times.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!