A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit. | LitMetric

Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit.

Ann Thorac Med

Department of Surgery, Division of Traumatology and Surgical Critical Care, University of Pennsylvania School of Medicine, 3440 Market Street, 1 Floor, Philadelphia, PA 19104-3335, USA.

Published: October 2007

Background: Esophageal Doppler monitoring (EDM) is utilized in numerous clinical settings. This study examines the relationship between pulmonary artery catheter (PAC) and EDM-derived hemodynamic parameters, concentrating on gender- and age-related EDM measurement biases.

Materials And Methods: Prospective study of EDM use in ventilated surgical ICU patients. Parameters examined included demographics, diagnosis, resuscitation endpoints, cardiac output (CO) and stroke volume from both devices, number of personnel and time needed to place equipment, time to data acquisition, duration of use, complications of placement.

Results: Fifteen patients (11 men, 4 women, mean age 47 years) were included. Most common diagnoses included trauma (7/15) and sepsis (4/15). Insertion time and time to data acquisition were shorter for EDM than for PAC (P<0.001). The EDM required an average of 1.1 persons to place (2.4 for PAC, P=0.002). Mean EDM utilization time was 12.4 h. There was a fair CO correlation between EDM and PAC (r = 0.647, P<0.001). Overall, the EDM underestimated CO relative to PAC (bias -1.42 +/- 2.08, 95% CI: -5.58-2.74), with more underestimation in women (mean bias difference of -1.16, P<0.001). No significant age-related measurement bias differences between PAC and EDM were noted. Significant reductions in lactate and norepinephrine requirement were noted following EDM monitoring periods.

Conclusions: This study found that the EDM significantly underestimated cardiac output in women when compared to PAC. Clinicians should be aware of this measurement bias when making therapeutic decision based on EDM data. Significant reductions in lactate and norepinephrine requirement during EDM monitoring periods support the clinical usefulness of EDM technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2732095PMC
http://dx.doi.org/10.4103/1817-1737.36548DOI Listing

Publication Analysis

Top Keywords

esophageal doppler
8
doppler monitoring
8
time data
8
data acquisition
8
exploring measurement
4
measurement biases
4
biases associated
4
associated esophageal
4
monitoring critically
4
critically ill
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!