We present an advanced system for on-line position-specific carbon isotope analysis. The main limitation of on-line intramolecular isotope ratio measurements has been that optimal pyrolytic fragments are obtained mostly at temperatures where the analyte has not completely reacted. As a result of undetermined isotopic fractionation, the isotopic signatures of the pyrolysis products are not strictly equal to these of the equivalent moieties in the parent molecule. We designed a pyrolytic unit in which both temperature and reaction time are variable parameters, enabling determination of the enrichment factor of the pyrolysis at optimal temperature by construction of a Rayleigh plot. In the case of methyl tert-butyl ether (MTBE) presented here, a 'pre-pyrolysis' fractionation of MTBE leading to a depletion of 0.9 per thousand was discovered and the enrichment factor of the optimal pyrolysis reaction was determined at -1.7 per thousand. Absolute delta(13)C values of two functional groups of MTBE - the methoxy group and the 2-methylpropane group - could be determined with 95% confidence intervals of 0.4 per thousand and 0.5 per thousand, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.4222DOI Listing

Publication Analysis

Top Keywords

on-line position-specific
8
carbon isotope
8
methyl tert-butyl
8
tert-butyl ether
8
enrichment factor
8
development advanced
4
advanced on-line
4
position-specific stable
4
stable carbon
4
isotope system
4

Similar Publications

Here, we report an update of the VDJdb database with a substantial increase in the number of T-cell receptor (TCR) sequences and their cognate antigens. The update further provides a new database infrastructure featuring two additional analysis modes that facilitate database querying and real-world data analysis. The increased yield of TCR specificity identification methods and the overall increase in the number of studies in the field has allowed us to expand the database more than 5-fold.

View Article and Find Full Text PDF

Rationale: The fundamental level of stable isotopic knowledge lies at specific atomic positions within molecules but existing methods of analysis require lengthy off-line preparation to reveal this information. An automated position-specific isotope analysis (PSIA) method is presented to determine the stable carbon isotopic compositions of the carboxyl groups of amino acids (δ C values). This automation makes PSIA measurements easier and routine.

View Article and Find Full Text PDF

Evaluation of on-line pyrolysis coupled to isotope ratio mass spectrometry for the determination of position-specific (13)C isotope composition of short chain n-alkanes (C6-C12).

Talanta

June 2016

Earth-Life Science Institute, Tokyo Institute of Technology, Meguro, Tokyo 152-8551, Japan; Department of Environmental Chemistry and Engineering, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503, Japan.

We measured (13)C intramolecular isotopic composition of commercially available short-chain hydrocarbons (n-C6-n-C12) using (13)C-NMR. Results show that the main variation is between the terminal and the sub-terminal C-atom positions. Site-preference (difference in δ(13)C values between terminal and sub-terminal C-atom positions) among all the samples varies between -12.

View Article and Find Full Text PDF

Differential motif enrichment analysis of paired ChIP-seq experiments.

BMC Genomics

September 2014

Institute for Molecular Bioscience, The University of Queensland, 306 Carmody Road, 4072 Brisbane, Australia.

Background: Motif enrichment analysis of transcription factor ChIP-seq data can help identify transcription factors that cooperate or compete. Previously, little attention has been given to comparative motif enrichment analysis of pairs of ChIP-seq experiments, where the binding of the same transcription factor is assayed under different conditions. Such comparative analysis could potentially identify the distinct regulatory partners/competitors of the assayed transcription factor under different conditions or at different stages of development.

View Article and Find Full Text PDF

We present an advanced system for on-line position-specific carbon isotope analysis. The main limitation of on-line intramolecular isotope ratio measurements has been that optimal pyrolytic fragments are obtained mostly at temperatures where the analyte has not completely reacted. As a result of undetermined isotopic fractionation, the isotopic signatures of the pyrolysis products are not strictly equal to these of the equivalent moieties in the parent molecule.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!