A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Percutaneous closure of inter-atrial communication with the Amplatzer device. Experience with 42 cases]. | LitMetric

[Percutaneous closure of inter-atrial communication with the Amplatzer device. Experience with 42 cases].

Arch Cardiol Mex

Departamento de Hemodinamia, Hospital General, Centro Médico Nacional La Raza (CMN La Raza), Instituto Mexicano del Seguro Social (IMSS), México, D.F. México.

Published: October 2009

We report our experience on 42 patients treated with atrial septal defect (ASD) occlusion using Amplatzer device. Thirty patients were females and 12 were males, mean ages 26.5-years-old +/- 12 years (interval from 7 to 69 years). Average weight was 57.1 +/- 13.8 kg (32.3-85.0 kg). Forty-two devices (ranging diameters from 13 mm to 40 mm) were deployed, 40 of which were placed successfully and attempts were unsuccessful in two cases (diameter devices 36 mm and 40 mm, respectively). We used the "balloon on the left or right upper pulmonary vein" in 5 patients, achieving good deployment. Echocardiography showed total occlusion in 37 patients (93.5%), trivial leak in 2 (4.7%), and light leak in 1 patient (2.3%). Follow up was at 1 to 12 months (mean 6.5). Total occlusion was observed at one month on both patients with trivial leak, and at 6 months on the patient with light leak. Failure to deploy the device appropriately on the two patients with unsuccessful result was due to unfavorable anatomy: very large defects in both cases (occluder size 36 mm and 40 mm), very thin postero-superior 6 mm rim on one of them and aortic rim absence on the other one. Stretched diameters were 34 mm and 38 mm on patients with 36 mm and 40 mm devices, respectively. Both of them were sent to surgery. We conclude that percutaneus closure of atrial septal defect with the Amplatzer device is a save and have good results.

Download full-text PDF

Source

Publication Analysis

Top Keywords

amplatzer device
12
atrial septal
8
septal defect
8
total occlusion
8
trivial leak
8
light leak
8
patients
7
[percutaneous closure
4
closure inter-atrial
4
inter-atrial communication
4