Acetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component: a 20- to 25-year follow-up.

J Bone Joint Surg Br

Department of Orthopaedics, Nijmegen Medical Centre, Radboud University, Intern postcode 357, P. O. Box 9101, 6500 HB Nijmegen, The Netherlands.

Published: September 2009

We present an update of the clinical and radiological results of 62 consecutive acetabular revisions using impacted morsellised cancellous bone grafts and a cemented acetabular component in 58 patients, at a mean follow-up of 22.2 years (20 to 25). The Kaplan-Meier survivorship for the acetabular component with revision for any reason as the endpoint was 75% at 20 years (95% confidence interval (CI) 62 to 88) when 16 hips were at risk. Excluding two revisions for septic loosening at three and six years, the survivorship at 20 years was 79% (95% CI 67 to 93). With further exclusions of one revision of a well-fixed acetabular component after 12 years during a femoral revision and two after 17 years for wear of the acetabular component, the survivorship for aseptic loosening was 87% at 20 years (95% CI 76 to 97). At the final review 14 of the 16 surviving hips had radiographs available. There was one additional case of radiological loosening and four acetabular reconstructions showed progressive radiolucent lines in one or two zones. Acetabular revision using impacted large morsellised bone chips (0.5 cm to 1 cm in diameter) and a cemented acetabular component remains a reliable technique for reconstruction, even when assessed at more than 20 years after surgery.

Download full-text PDF

Source
http://dx.doi.org/10.1302/0301-620X.91B9.21750DOI Listing

Publication Analysis

Top Keywords

acetabular component
24
cemented acetabular
12
acetabular
10
acetabular revision
8
revision impacted
8
impacted morsellised
8
morsellised cancellous
8
cancellous bone
8
years
8
years 95%
8

Similar Publications

Background: Periprosthetic hip dislocation after total hip arthroplasty is a devastating postoperative complication. It is often associated with suboptimal orientation of the acetabular component, characterized by the acetabular abduction and anteversion angles obtained from anteroposterior pelvic radiographs. We introduce a novel automated web tool to streamline the subjective and lengthy process of this manual measurement and compare it to manual human measurements.

View Article and Find Full Text PDF

Dislocation is the second most common indication for revision total hip arthroplasty (THA). In revision cases the dislocation rate can be as high as 5-30%. The aim of this study was to assess the outcome, specifically the dislocation rate in revision THA where a dual mobility cup was used.

View Article and Find Full Text PDF

Several studies suggested that total hip arthroplasty (THA) was more technical demanding following previous pelvic osteotomy (PO), resulting in poor outcomes compared with primary THA. However, the other studies regarding this topic had reported contradictory results. Therefore, we conducted this meta-analysis to compare the clinical results and other parameters between total hip arthroplasty following pelvic osteotomy and primary total hip arthroplasty.

View Article and Find Full Text PDF

Large-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.

View Article and Find Full Text PDF

Background: The ideal anteversion at which the acetabular and femoral components for a total hip arthroplasty (THA) should be implanted is still a subject of debate. One alignment philosophy being explored is restoration of individual constitutional femoral and acetabular anteversion. This study aimed to measure combined anteversion in a healthy hip population and understand the expected phenotypes and ranges for constitutional hip alignment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!