A new method for hemorrhoid surgery: intrahemorrhoidal diode laser, does it work?

Photomed Laser Surg

Universidade Federal de São Paulo (UNIFESP), São Paulo, Brazil.

Published: October 2009

Objective: This study aimed to describe the clinical results of intrahemorrhoidal application of a diode laser.

Background Data: Hemorrhoids are a common source of pain, and no surgical technique achieves a painless outcome. Endovascular laser therapy for varicose veins as described in an experimental study is a method that could be used in the treatment of hemorrhoids, but there are few clinical trials described in the literature.

Materials And Methods: Fifteen patients with second and third degree hemorrhoids underwent intrahemorrhoidal laser therapy. After the piles were identified, a fiber was introduced into each and it was irradiated with laser energy (810 nm, 5 W, frequency of 5 Hz, energy density of 19 J/cm(2), total energy of 4-10 J).

Results: The piles were immediately partially reduced, and clinical examination 7, 14, 21, and 28 d after surgery showed complete healing in nine patients (60.4%) and partial resolution in five patients (33%). In one patient (6.6%) the treatment failed. Mean pain intensity throughout the study period, measured by a visual analog scale (0-10), was 0.84 +/- 1.13 (mean +/- SD). Major complications were burn lesions (n = 4) and residual plicoma (skin tag) (n = 5). Ten control patients underwent an open "cold scalpel" hemorrhoidectomy. Their pain intensity was 1.78 +/- 0.68 (mean +/- SD). There was a significant statistical difference (p = 0.018) between groups.

Conclusion: The diode laser energy delivered into small to median hemorrhoidal piles caused little pain and led to a partial to complete resolution within a short time compared to open hemorrhoidectomy. Some adjustments must be made to prevent burning lesions and residual plicoma. Although it is not a good method for big piles, this technique opens new possibilities for surgical treatment of hemorrhoidal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1089/pho.2008.2368DOI Listing

Publication Analysis

Top Keywords

diode laser
8
laser therapy
8
laser energy
8
pain intensity
8
lesions residual
8
residual plicoma
8
laser
5
method hemorrhoid
4
hemorrhoid surgery
4
surgery intrahemorrhoidal
4

Similar Publications

Oral candidiasis, predominantly caused by , presents significant challenges in treatment due to increasing antifungal resistance and biofilm formation. Antimicrobial photodynamic therapy (aPDT) using natural photosensitizers like riboflavin and hypericin offers a potential alternative to conventional antifungal therapies. : A systematic review was conducted to evaluate the efficacy of riboflavin- and hypericin-mediated aPDT in reducing Candida infections.

View Article and Find Full Text PDF

Mid-infrared spectral analysis has long been recognized as the most accurate noninvasive blood glucose measurement method, yet no practical compact mid-infrared blood glucose sensor has ever passed the accuracy benchmark set by the USA Food and Drug Administration (FDA): to substitute for the finger-pricking glucometers in the market, a new sensor must first show that 95% of their glucose measurements have errors below 15% of these glucometers. Although recent innovative exploitations of the well-established Fourier-transform infrared (FTIR) spectroscopy have reached such FDA accuracy benchmarks, an FTIR spectrometer is too bulky. The advancements of quantum cascade lasers (QCLs) can lead to FTIR spectrometers of reduced size, but compact QCL-based noninvasive blood glucose sensors are not yet available.

View Article and Find Full Text PDF

Single-Photon Avalanche Photodiodes (SPADs) are increasingly utilized in high-temperature-operated, high-performance Light Detection and Ranging (LiDAR) systems as well as in ultra-low-temperature-operated quantum science applications due to their high photon sensitivity and timing resolution. Consequently, the jitter value of SPADs at different temperatures plays a crucial role in LiDAR systems and Quantum Key Distribution (QKD) applications. However, limited studies have been conducted on this topic.

View Article and Find Full Text PDF

Background: Sensory disturbances and acquired paresthesia constitute a significant proportion of complications following orthognathic surgery. This systematic review examines the application of photobiomodulation (PBM) in managing these complications and its efficacy in promoting sensory recovery.

Methods: In November 2024, a comprehensive digital search was performed across reputable databases, including PubMed, Web of Science, and Scopus, using carefully selected search terms: "orthognathic surgery" AND (physiotherapy OR physical therapy OR laser OR LLLT OR PBM OR light OR LED OR acupuncture) AND (nerve OR neurosensory OR paresthesia).

View Article and Find Full Text PDF

Background: The non-ablative 1940-nm laser induces controlled thermal damage at superficial depths without ablating the epidermis.

Objective: We evaluated a new 1940-nm fractional diode laser for improving pigmentation and skin texture.

Materials And Methods: Participants with mild to severe benign pigmented lesions received up to three laser treatments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!