A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intraoperative X-ray detection and MRI-based quantification of brain shift effects subsequent to implantation of the first electrode in bilateral implantation of deep brain stimulation electrodes. | LitMetric

AI Article Synopsis

  • The study aims to quantify brain shift effects in patients undergoing bilateral deep brain stimulation (DBS) lead implantation using intraoperative MRI and investigate the use of X-ray imaging for indirect detection of these shifts.
  • In 25 patients, significant brain shifts were observed, with a maximum shift of 1.3 mm at the anterior-posterior commissure line and up to 2.5 mm along the trajectory of the second electrode, which may lead to electrode misplacement.
  • The presence of intracranial air, detected via MRI, was associated with changes in X-ray absorption, suggesting that large volumes of air could impact the accuracy of electrode placement, highlighting the importance of monitoring brain shift during surgery.

Article Abstract

Objective: After implantation of the first electrode in bilateral deep brain stimulation (DBS) lead implantation, brain shift effects in the target region and along the implantation trajectory of the second electrode are quantified with intraoperative magnetic resonance imaging (MRI). We investigated intraoperative X-ray imaging for its feasibility in indirect detection of brain shift.

Methods: In 25 patients who underwent bilateral DBS lead implantation, X-ray and MRI were performed before and after implantation of the first electrode. Two parameters of brain shift were assessed with nonrigid free-form deformation field analysis of the MRI data: global brain shift along the anterior and posterior commissure (AC-PC) line and specific brain shift along the implantation trajectory of the second electrode. Pre- and intraoperative X-ray images were geometrically and intensity corrected for detection of significant signal changes through intracranial air accumulation during implantation of the first electrode.

Results: After implantation of the first electrode, brain shift greater than 1 mm (maximum 1.3 mm) was observed at the AC and brain shift greater than 2 mm (maximum 2.5 mm) was observed along the planned implantation trajectory of the second electrode. In 1 patient, the implantation trajectory of the second electrode went through a sulcus after cortical brain shift. In 9 patients, intracranial air volume between 0.1 and 38.5 ml was observed with MRI after implantation of the first electrode. Significant X-ray absorption changes were induced by an intracranial air volume of greater than 8 ml.

Conclusion: In bilateral DBS implantation, brain shift effects can cause misallocation of the second electrode with the risk of adverse or no stimulation effects as well as unnecessary cortical damage. A lack of X-ray signal changes caused by intracranial air invasion during DBS lead implantation indicates a lack of clinically relevant brain shift.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000235804DOI Listing

Publication Analysis

Top Keywords

brain shift
40
implantation electrode
20
second electrode
20
implantation trajectory
16
trajectory second
16
intracranial air
16
implantation
15
brain
13
intraoperative x-ray
12
shift effects
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!