The IMCA-CAT bending-magnet beamline was upgraded with a collimating mirror in order to achieve the energy resolution required to conduct high-quality multi- and single-wavelength anomalous diffraction (MAD/SAD) experiments without sacrificing beamline flux throughput. Following the upgrade, the bending-magnet beamline achieves a flux of 8 x 10(11) photons s(-1) at 1 A wavelength, at a beamline aperture of 1.5 mrad (horizontal) x 86 microrad (vertical), with energy resolution (limited mostly by the intrinsic resolution of the monochromator optics) deltaE/E = 1.5 x 10(-4) (at 10 kV). The beamline operates in a dynamic range of 7.5-17.5 keV and delivers to the sample focused beam of size (FWHM) 240 microm (horizontally) x 160 microm (vertically). The performance of the 17-BM beamline optics and its deviation from ideally shaped optics is evaluated in the context of the requirements imposed by the needs of protein crystallography experiments. An assessment of flux losses is given in relation to the (geometric) properties of major beamline components.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049509022353DOI Listing

Publication Analysis

Top Keywords

bending-magnet beamline
12
flux throughput
8
imca-cat bending-magnet
8
beamline
8
energy resolution
8
focusing collimation
4
flux
4
collimation flux
4
throughput imca-cat
4
beamline advanced
4

Similar Publications

GIWAXS experimental methods at the NFPS-BL17B beamline at Shanghai Synchrotron Radiation Facility.

J Synchrotron Radiat

July 2024

National Facility for Protein Science in Shanghai, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Pudong District, People's Republic of China.

The BL17B beamline at the Shanghai Synchrotron Radiation Facility was first designed as a versatile high-throughput protein crystallography beamline and one of five beamlines affiliated to the National Facility for Protein Science in Shanghai. It was officially opened to users in July 2015. As a bending magnet beamline, BL17B has the advantages of high photon flux, brightness, energy resolution and continuous adjustable energy between 5 and 23 keV.

View Article and Find Full Text PDF

The beamline optics and endstations at branch B of the Versatile Soft X-ray (VerSoX) beamline B07 at Diamond Light Source are described. B07-B provides medium-flux X-rays in the range 45-2200 eV from a bending magnet source, giving access to local electronic structure for atoms of all elements from Li to Y. It has an endstation for high-throughput X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine-structure (NEXAFS) measurements under ultrahigh-vacuum (UHV) conditions.

View Article and Find Full Text PDF

A versatile beamline for performing reflectivity, fluorescence, and absorption experiments in the soft x-ray region of 100-1500 eV is commissioned on a bending magnet port of the Indus-2 synchrotron source. A high vacuum 2-axis reflectometer with x, y, and z sample scanning stages is installed. This reflectometer is used to measure the reflectivity of large samples up to 300 mm in length and 5 kg in weight.

View Article and Find Full Text PDF

A Small- and Wide-Angle X-ray Scattering (SWAXS) beamline (BL-18) is installed and commissioned at a 1.5 T bending magnet port (5°) of Indus-2 synchrotron at RRCAT, Indore, India. The ∼40-m-long beamline has tunable x-ray energy in the range of 5-20 keV by using a double crystal monochromator.

View Article and Find Full Text PDF

An active piezoelectric plane X-ray focusing mirror with a linearly changing thickness.

J Synchrotron Radiat

January 2024

Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute, Chinese Academy of Sciences, 239 Zhangheng Road, Pudong District, Shanghai 201204, People's Republic of China.

X-ray mirrors for synchrotron radiation are often bent into a curved figure and work under grazing-incidence conditions due to the strong penetrating nature of X-rays to most materials. Mirrors of different cross sections have been recommended to reduce the mirror's slope inaccuracy and clamping difficulty in order to overcome mechanical tolerances. With the development of hard X-ray focusing, it is difficult to meet the needs of focusing mirrors with small slope error with the existing mirror processing technology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!