Advances in genomics continue to fuel the development of therapeutics that can target pathogenesis at the cellular and molecular level. Typically functional inside the cell, nucleic acid-based therapeutics require an efficient intracellular delivery system. One widely adopted approach is to complex DNA with a gene carrier to form nanocomplexes via electrostatic self-assembly, facilitating cellular uptake of DNA while protecting it against degradation. The challenge lies in the rational design of efficient gene carriers, since premature dissociation or overly stable binding would be detrimental to the cellular uptake and therapeutic efficacy. Nanocomplexes synthesized by bulk mixing showed a diverse range of intracellular unpacking and trafficking behavior, which was attributed to the heterogeneity in size and stability of nanocomplexes. Such heterogeneity hinders the accurate assessment of the self-assembly kinetics and adds to the difficulty in correlating their physical properties to transfection efficiencies or bioactivities. We present a novel convergence of nanophotonics (i.e. QD-FRET) and microfluidics to characterize the real-time kinetics of the nanocomplex self-assembly under laminar flow. QD-FRET provides a highly sensitive indication of the onset of molecular interactions and quantitative measure throughout the synthesis process, whereas microfluidics offers a well-controlled microenvironment to spatially analyze the process with high temporal resolution (~milliseconds). For the model system of polymeric nanocomplexes, two distinct stages in the self-assembly process were captured by this analytic platform. The kinetic aspect of the self-assembly process obtained at the microscale would be particularly valuable for microreactor-based reactions which are relevant to many micro- and nano-scale applications. Further, nanocomplexes may be customized through proper design of microfludic devices, and the resulting QD-FRET polymeric DNA nanocomplexes could be readily applied for establishing structure-function relationships.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2994720PMC
http://dx.doi.org/10.3791/1432DOI Listing

Publication Analysis

Top Keywords

qd-fret microfluidics
8
nanocomplex self-assembly
8
cellular uptake
8
self-assembly process
8
self-assembly
6
nanocomplexes
6
combining qd-fret
4
microfluidics monitor
4
dna
4
monitor dna
4

Similar Publications

Combinatorial screening is frequently used to identify chemicals with synergistic effects by measuring the response of biological entities exposed to various chemical-dose combinations. Conventional microwell-based combinatorial screening is resource-demanding, and the closed microfluidics-based screening requires sophisticated fluidic control systems. In this work, we present a novel combinatorial screening platform based on the surface energy trap (SET)-assisted magnetic digital microfluidics.

View Article and Find Full Text PDF

A microfluidic based solid-phase assay for the multiplexed detection of nucleic acid hybridization using quantum dot (QD) mediated fluorescence resonance energy transfer (FRET) is described herein. The glass surface of hybrid glass-polydimethylsiloxane (PDMS) microfluidic channels was chemically modified to assemble the biorecognition interface. Multiplexing was demonstrated using a detection system that was comprised of two colors of immobilized semi-conductor QDs and two different oligonucleotide probe sequences.

View Article and Find Full Text PDF

Quantum dot enabled molecular sensing and diagnostics.

Theranostics

October 2012

1. Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21205, USA.

Since its emergence, semiconductor nanoparticles known as quantum dots (QDs) have drawn considerable attention and have quickly extended their applicability to numerous fields within the life sciences. This is largely due to their unique optical properties such as high brightness and narrow emission band as well as other advantages over traditional organic fluorophores. New molecular sensing strategies based on QDs have been developed in pursuit of high sensitivity, high throughput, and multiplexing capabilities.

View Article and Find Full Text PDF

Micro Magnetic Gyromixer for Speeding up Reactions in Droplets.

Microfluid Nanofluidics

March 2012

Department of Biomedical Engineering, Johns Hopkins University. Clark 122, 3400 North Charles Street, Baltimore, MD 21218, USA.

We report a novel micro magnetic gyromixer designed for accelerating mixing hence reactions in droplets. The gyromixer is fabricated with magnetite-PDMS composite using soft lithography. The mixer spins and balances itself on the droplet surface through the gyroscopic effect, rapidly homogenizing the enclosed reagents by stretching and folding internal fluid streamlines to enhance mixing.

View Article and Find Full Text PDF

This study demonstrates the use of carrier-protein/haptens conjugate (e.g., BSA/2,4-dichlorophenoxyacetic acid, 2,4-D-BSA) for biological modification of quantum dots (QDs) for the detection of small analytes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!