Ejection fraction/velocity ratio identifies prosthesis-patient mismatches in patients with aortic bioprosthetic valves and left ventricular dysfunction.

J Ultrasound Med

Department of Cardiology and Intensive Cardiac Rehabilitation, Istituto Di Ricovero e Cura a Carattere Scientifico Multimedica Holding, Castellanza VA, Italy.

Published: September 2009

Objectives: Recently, a new echocardiographic nonflow corrected index (ejection fraction/velocity ratio [EFVR] = percent left ventricular ejection fraction [EF]/maximum aortic gradient) has been introduced and has shown excellent accuracy in quantifying the effective orifice area (EOA) in native aortic valves and bio-prostheses. The objective of this study was to assess the utility of the EFVR to quantify the indexed EOA in patients with an aortic bioprosthesis and left ventricular dysfunction considering an indexed EOA value of 0.85 cm(2)/m(2) or less to be indicative of a prosthesis-patient mismatch (PPM), defined as an EOA of the inserted prosthetic valve of less than that of the normal human valve.

Methods: We studied 100 patients (62 men and 38 women; mean age +/- SD, 71 +/- 8.6 years) with an aortic bioprosthesis and left ventricular dysfunction (EF < or =49%), and we evaluated the indexed EOA by both the continuity equation (CE) and EFVR.

Results: We found a significant linear correlation between the CE and EFVR (r = 0.85; P < .0001) and good agreement between the two methods in identifying patients with an indexed EOA of 0.85 cm(2)/m(2) or less; the correlation began to become nonlinear for patients with an indexed EOA of greater than 1.2 cm(2)/m(2), which was not clinically relevant. Notably, all 11 patients with a discrepancy between the indexed EOA and EFVR (ie, EFVR < or =1.0 and indexed EOA >0.85 cm(2)/m(2)) also showed an indexed EOA of greater than 0.85 but less than or equal to 1.0 cm(2)/m(2) (meaning the presence of a mild PPM).

Conclusions: The EFVR can be considered a reliable echocardiographic alternative to the CE, especially in conditions in which that is technically difficult, allowing identification of a PPM (indexed EOA < or =0.85 cm(2)/m(2)) with excellent sensitivity and specificity.

Download full-text PDF

Source
http://dx.doi.org/10.7863/jum.2009.28.9.1167DOI Listing

Publication Analysis

Top Keywords

indexed eoa
36
left ventricular
16
ventricular dysfunction
12
eoa
11
indexed
9
ejection fraction/velocity
8
fraction/velocity ratio
8
patients aortic
8
aortic bioprosthesis
8
bioprosthesis left
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!