Statement Of Problem: The retentive capacity of ball attachments may be altered by a change in implant angulations.
Purpose: The purpose of this in vitro study was to investigate the effect of cyclic dislodgement on the retention of an overdenture attachment system when 2 implants were placed at angulations of 0, 5, 10, 15, and 20 degrees.
Material And Methods: Twelve acrylic resin blocks were fabricated and divided into 6 groups of 2 pairs each. In each of the 6 groups, 1 acrylic resin block was used to house the implants (block A), while the other (block B) was used to house the overdenture attachments. Two implants positioned at 0/0 degrees, with a standard plastic component(white) designed for 0-degree angulations, served as a control (CTRL), while the other 5 pairs of implants were placed in 5 different angulations: 0D: 0/0 degrees, 5D: 5/5 degrees, 10D: 10/10 degrees, 15D: 15/15 degrees, 20D: 20/20degrees (n=5). The extended range (green color) attachment was used for all groups except the control group. Implants(4.3 mm x 13 mm, internally hexed) were placed in blocks B. All angled implants were mesially tilted. Thirty pairs of attachments (Locator) were used. Dislodging cycles were applied to the overdenture attachment system. The initial retentive forces among the groups were not identical. The cycles required for the retentive forces of the attachments to decrease from the initial values to 60 N, and then to 40 N and 20 N, were recorded for standardization purposes.One-way ANOVA and Tukey HSD tests were used to analyze the difference in retention loss among the 6 groups(alpha=.05). A regression analysis (alpha=.05) was also performed to investigate the relationship between the implant angulation,the retentive force, and the logarithm of the number of cycles required for ball attachment retention decrease.
Results: The 1-way ANOVA and the Tukey HSD tests revealed significant differences for the number of cycles required by different implant angulation groups for the initial retentive values to decrease to 60 N, 40 N, and 20 N (P<.001).The 0D and 5D groups required the longest time for retention loss, while 20D and CTRL groups demonstrated the shortest time for retention loss. The results of the regression analysis of the logarithmic number of cycles on retentive force and implant angulation demonstrated a significant effect (P<.001).
Conclusions: Implant angulations negatively affect attachment retention longevity. (J Prosthet Dent 2009;102:140-147)
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0022-3913(09)60134-7 | DOI Listing |
J Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
Dent Mater J
December 2024
Mechanical Engineering, Faculty of Engineering, Atatürk University.
This study aimed to apply finite element analysis (FEA) to simulate the oral environment of a patient with an implant-supported overdenture prosthesis. A 3D mandibular model was created for a 45-year-old female patient from CT images, with mucosal thickness measured at 3 mm on average using ultrasonography. The overdenture prosthesis was scanned with an intraoral scanner and placed onto the 3D mandibular model.
View Article and Find Full Text PDFBMC Res Notes
December 2024
Department of Oral Medicine and Periodontology, Faculty of Dental Sciences, University of Peradeniya, Peradeniya, Sri Lanka.
Objective: To compare the effectiveness of prosthetic rehabilitation of edentulous patients using conventional complete dentures (CD), single median dental implant retained over dentures (SIMOD) with over dentures retained by two dental implants (TIMOD).
Methods: Thirty completely edentulous patients (fifteen each arm) presented to the Faculty of Dental Sciences, University of Peradeniya were randomly selected for the SIMOD or TIMOD groups. Patients were initially provided with CD.
Dent Med Probl
December 2024
Department of Fixed and Removable Prosthodontics, National Research Center, Cairo, Egypt.
J Prosthodont
December 2024
Department of Prosthodontics, Hacettepe University Faculty of Dentistry Sıhhiye, Ankara, Turkey.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!