Aberration effects on femtosecond pulses generated by nonideal achromatic doublets.

Appl Opt

Centro de Ciencias Aplicadas y Desarrollo Tecnológico, Universidad Nacional Autónoma de México, Circuito Exterior, Cd. Universitaria, 04510, Mexico D.F., Apdo. Postal 70-186.

Published: August 2009

There are three main effects that affect the femtosecond pulse focusing process near the focal plane of a refractive lens: the group velocity dispersion (GVD), the propagation time difference (PTD), and the aberrations of the lens. In this paper we study in detail these effects generated by nonideal achromatic doublets based on a Fourier-optical analysis and Seidel aberration theory considering lens material, wavelength range, lens surface design, and temporally and spatially uniform and Gaussian intensity distributions. We show that the residual chromatic aberration in achromatic lenses, which has been neglected so far, has a considerable effect on the focusing of pulses shorter than 20 fs in the spectral range between the UV and IR, 300 to 1100 nm, and is particularly important in the blue and UV spectral range. We present a general fitted function for an estimation of the pulse stretching parameter, which depends only on the numerical aperture and focal length of the doublet as well as the wavelength of the carrier of the pulse.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.48.004723DOI Listing

Publication Analysis

Top Keywords

generated nonideal
8
nonideal achromatic
8
achromatic doublets
8
spectral range
8
aberration effects
4
effects femtosecond
4
femtosecond pulses
4
pulses generated
4
doublets three
4
three main
4

Similar Publications

Ion exchange membranes (IEMs) are permselective membranes that, in principle, only allow the flow of ions with a specific charge sign, opposite to that of the fixed membrane ionic groups (counter-ions). This charge-based selectivity, like the size-based selectivity of classic semipermeable membranes, leads to an uneven distribution of permeating ions on the two sides of the membrane, which allows for ion separation or recovery in various processes in industry or environmental protection. Here, we apply the principles of mass balance, charge neutrality, and equality of electrochemical potentials in the state of thermodynamic equilibrium to provide a simple method for estimating the Gibbs-Donnan factors and the equilibrium concentrations of permeating ions in two compartments separated by an ideal IEM, i.

View Article and Find Full Text PDF

This study proposes an image enhancement detection technique based on Adltformer (Adaptive dynamic learning transformer) team-training with Detr (Detection transformer) to improve model accuracy in suboptimal conditions, addressing the challenge of detecting cattle in real pastures under complex lighting conditions-including backlighting, non-uniform lighting, and low light. This often results in the loss of image details and structural information, color distortion, and noise artifacts, thereby compromising the visual quality of captured images and reducing model accuracy. To train the Adltformer enhancement model, the day-to-night image synthesis (DTN-Synthesis) algorithm generates low-light image pairs that are precisely aligned with normal light images and include controlled noise levels.

View Article and Find Full Text PDF

Background: This study aims to evaluate the long-term outcomes of patients with large coronary arteries (LCA, reference vessel diameter more than 3.0 mm) de novo lesions treated by drug-coated balloon (DCB) versus second-generation drug-eluting stent (sDES) in real-world clinical practice.

Methods: Between January 2020 and June 2021, 2857 consecutive patients with equal number of LCA de novo lesions, including 708 lesions treated with paclitaxel DCB-only (DCB-only cohort) and 2149 lesions with sDES-only (sDES-only cohort), were enrolled in this retrospective study.

View Article and Find Full Text PDF
Article Synopsis
  • Heterodyne phase-sensitive dispersion spectroscopy (HPSDS) is a non-intrusive gas sensing method that relies on measuring the refractive index near gas absorption transitions, making it less affected by laser intensity fluctuations.
  • Traditional HPSDS sensors require calibration with standard gas mixtures, which can be difficult and unreliable, particularly with varying gas compositions; this study introduces a new approach that allows for fully calibration-free measurements.
  • The researchers developed a novel analytical model for HPSDS that integrates various modulation techniques and tested it successfully with gases like CH, NO, and NH, demonstrating its effectiveness across different laser types and conditions.
View Article and Find Full Text PDF

In Industrial Internet of Things (IIoT) production and operation processes, a substantial amount of video data is generated, often containing sensitive personal and commercial information. This paper proposed three new multiscroll Hopfield neural network (MHNN) systems by utilizing an improved segmented nonlinear non-ideal magnetic-controlled memristor model for electromagnetic radiation. Through dynamical methods, the constructed neural network's multidimensional multiscroll attractors and initial offset boosting behavior are analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!