Automatic implementation of precise grid screens: the four-corners method.

Acta Crystallogr D Biol Crystallogr

Department of Biological Sciences, 312 Clapp Hall, University of Pittsburgh, Pittsburgh, PA 15260, USA.

Published: September 2009

Crystallization trials can be designed as a systematic gradient of the concentration of key reagents and/or pH centered on the original conditions. While the concept of the grid screen is simple, its implementation is tedious and difficult by hand. A procedure has been developed for preparing crystallization grid screens that is both efficient and achieves high accuracy because it relies on a limited number of solutions that are carefully prepared by hand. The ;four-corners' approach to designing grid screens uses the minimum and maximum concentrations of the components being varied in the grid screen as the sole stock solutions. For an N-dimensional grid only 2(N) corner solutions require detailed preparation, making the screens efficient. Furthermore, by keeping the concentrations as tight as possible to the grid, the potential impact of pipette errors is minimized, creating a highly precise screen.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2733884PMC
http://dx.doi.org/10.1107/S0907444909020320DOI Listing

Publication Analysis

Top Keywords

grid screens
12
grid screen
8
screens efficient
8
grid
7
automatic implementation
4
implementation precise
4
precise grid
4
screens
4
screens four-corners
4
four-corners method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!