The reference measurement procedure for determination of HbA(1c) (glycated haemoglobin) using HPLC(high performance liquid chromatography)-ESI(electrospray ionisation)-MS(mass spectrometry) has been modified. Main modifications were a change in the buffer composition of the HPLC, a change in the gradient elution profile and the introduction of a post-column splitting system. The long-term stability of the HPLC-ESI-MS system proved to be of high importance to get reproducible results. Using the modified HPLC conditions stable retention times, high peak symmetry and a good column batch-to-batch reproducibility of the analytical results were obtained. The mean deviation from the target values was less than 0.7% with an imprecision of less than 2%.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2703220PMC

Publication Analysis

Top Keywords

reference measurement
8
measurement procedure
8
procedure determination
8
modification ifcc
4
ifcc reference
4
determination hba
4
hba hplc-esi-ms
4
hplc-esi-ms reference
4
determination hba1c
4
hba1c glycated
4

Similar Publications

Background: Cigarette smoking is a leading cause of death and disease, including those related to the cardiovascular system. Cytisine is a plant-based medication, which works in a similar mechanism to varenicline. It is safe, efficacious, and cost-effective for smoking cessation.

View Article and Find Full Text PDF

Background: The link between obesity and cardiometabolic risk has been well recognized. We investigated the association between body fat percentage (BF%), as an appropriate indicator of obesity, and prevalence of cardiometabolic diseases using baseline data of Fasa PERSIAN cohort study.

Methods: The cross-sectional study was performed on data obtained at the first phase of the Fasa cohort study in Iran (n = 4658: M/F: 2154/2504).

View Article and Find Full Text PDF

Abnormal characteristics of inferior vena cava and abdominal aorta among neonates with early onset septic shock.

Ital J Pediatr

January 2025

Department of Neonatology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao tong University, Shanghai, China.

Background: The variety of shocks in neonates, if not recognized and treated immediately, is a major cause for fatality. The use of echocardiography may improve assessment and treatment, but its reference values across gestational age (GA) and birth weight (BW) are lacking. To address the information gap, this study aimed at correlating GA and BW of newborns with nonhemodynamic abnormalities, and at evaluating the usefulness of such reference values in neonates with early onset septic (EOS) -shock.

View Article and Find Full Text PDF

Association between metabolic score for visceral fat index and BMI-adjusted skeletal muscle mass index in American adults.

Lipids Health Dis

January 2025

Department of Orthopedics, The 921st Hospital of the People's Liberation Army, The Second Affiliated Hospital of Hunan Normal University, Changsha, 410003, People's Republic of China.

Background: The metabolic score for visceral fat (METS-VF) is a recently identified index for evaluating visceral fat, also referred to as abdominal obesity. The skeletal muscle mass index (SMI) serves as a critical measure for assessing muscle mass and sarcopenia. Both obesity and the reduction of muscle mass can significantly affect human health.

View Article and Find Full Text PDF

Background: Workplace health screening rarely includes measures of cardiorespiratory fitness, despite it being a greater predictor of cardiovascular disease and all-cause mortality than other routinely measured risk factors. This study aimed to determine the comparative acceptability of using a novel seismocardiography device to measure cardiorespiratory fitness via VO max during a workplace health check.

Methods: Participants were invited to participate in workplace health screening sessions where VO max was assessed by both seismocardiography at rest and sub-maximal exercise testing, in order for acceptability of both to be compared across multiple domains.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!