A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assays for the quantification of melphalan and its hydrolysis products in human plasma by liquid chromatography-tandem mass spectrometry. | LitMetric

Assays for the quantification of melphalan and its hydrolysis products in human plasma by liquid chromatography-tandem mass spectrometry.

J Chromatogr B Analyt Technol Biomed Life Sci

Laboratoire de ciblage thérapeutique en cancérologie, Hospices Civils de Lyon, Centre Hospitalier Lyon-Sud, F-69495 Pierre Bénite, France.

Published: October 2009

Two high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assays are described for the quantification of melphalan in human plasma. N-phenyldiethanolamine was tested as internal standard. The first assay consisted of a protein precipitation by cold methanol and a reversed-phase HPLC whereas the second one was based on a solid phase extraction and a hydrophilic interaction chromatography. Both provided a very satisfactory mean extraction yield with a small volume of sample. The first method was simple, rapid and used as a routine assay. The second one was developed in order to determine melphalan hydrolysis products and to avoid scarce cases when interferences from biological matrix alter the quantification of melphalan using the first method. The two assays were linear and sensitive in the range of 1-500ng/mL for the first one and in a range of 25-2000ng/mL for the second one. Concentrations out of the range fixed with the first method were also validated. The procedure was reliable with precision and accuracy below 10%. All compounds were detected after positive mode electrospray ionization in selected reaction monitoring mode. These new analytical procedures were developed for melphalan pharmacokinetic studies or therapeutic drug monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2009.07.033DOI Listing

Publication Analysis

Top Keywords

quantification melphalan
12
melphalan hydrolysis
8
hydrolysis products
8
human plasma
8
mass spectrometry
8
melphalan
5
assays quantification
4
products human
4
plasma liquid
4
liquid chromatography-tandem
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!