A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Threshold concentration of easily assimilable organic carton in feedwater for biofouling of spiral-wound membranes. | LitMetric

AI Article Synopsis

  • The study investigates how the presence of acetate, an organic compound, in feedwater affects clogging in spiral-wound membranes used for water treatment.
  • The experiment utilized a membrane fouling simulator to analyze pressure changes in the feed channel when acetate concentrations ranged from 1 to 1000 microg C x L(-1).
  • Results showed that pressure drops increased with acetate levels, with a maximum fouling rate achieved at 25 microg acetate-C x L(-1), indicating biofouling begins at concentrations as low as 1 microg acetate-C x L(-1).

Article Abstract

One of the major impediments in the application of spiral-wound membranes in water treatment or desalination is clogging of the feed channel by biofouling which is induced by nutrients in the feedwater. Organic carbon is, under most conditions, limiting the microbial growth. The objective of this study is to assess the relationship between the concentration of an easily assimilable organic compound such as acetate in the feedwater and the pressure drop increase in the feed channel. For this purpose the membrane fouling simulator (MFS) was used as a model for the feed channel of a spiral-wound membrane. This MFS unit was supplied with drinking water enriched with acetate at concentrations ranging from 1 to 1000 microg C x L(-1). The pressure drop (PD) in the feed channel increased at all tested concentrations but not with the blank. The PD increase could be described by a first order process based on theoretical considerations concerning biofilm formation rate and porosity decline. The relationship between the first order fouling rate constant R(f) and the acetate concentration is described with a saturation function corresponding with the growth kinetics of bacteria. Under the applied conditions the maximum R(f) (0.555 d(-1)) was reached at 25 microg acetate-C x L(-1) and the half saturation constant k(f) was estimated at 15 microg acetate-C x L(-1). This value is higher than k(s) values for suspended bacteria grown on acetate, which is attributed to substrate limited growth conditions in the biofilm. The threshold concentration for biofouling of the feed channel is about 1 microg acetate-C x L(-1).

Download full-text PDF

Source
http://dx.doi.org/10.1021/es900037xDOI Listing

Publication Analysis

Top Keywords

feed channel
20
microg acetate-c
12
acetate-c l-1
12
threshold concentration
8
concentration easily
8
easily assimilable
8
assimilable organic
8
spiral-wound membranes
8
pressure drop
8
feed
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!