A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel electronic algorithm for detecting potentially insufficient anesthesia: implications for the prevention of intraoperative awareness. | LitMetric

Objective: A recent clinical trial compared a minimum alveolar concentration (MAC)-based protocol to an electroencephalography (EEG)-based protocol for the prevention of intraoperative awareness. One limitation of this study design is that MAC-based protocols are not sensitive to the use of intravenous agents, while EEG-based protocols are. Our objective was to develop a MAC alert that incorporates intravenous agents.

Methods: We developed an electronic algorithm and alerting system that calculates a total age-adjusted MAC value based on inhalational agents, but also incorporates intravenous agents. We retrospectively applied the algorithm to adult general anesthesia cases over a 1 year period to assess the frequency of alert triggers, using thresholds of <0.8, <0.7, <0.6, <0.5 and <0.4 age-adjusted MAC. We also electronically analyzed 12 cases of intraoperative awareness that occurred over a 4-year period for the frequency of alert triggers using the same thresholds. Finally, we calculated positive and negative likelihood ratios based on these analyses.

Results: Over a 1-year period we identified 15,091 cases without self-reported awareness that were valid for analysis. At all age-adjusted MAC thresholds, the incidence of triggered alerts was higher in the awareness cases. The threshold of<0.8 age-adjusted MAC was associated with the highest negative likelihood ratio; the<0.5 age-adjusted MAC was associated with the highest positive likelihood ratio.

Conclusions: Our novel electronic alerting system incorporates both age-adjusted MAC and intravenous anesthesia, and triggers with a higher frequency in cases of awareness. These data suggest the potential for our system to alert clinicians to insufficient anesthesia.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10877-009-9193-9DOI Listing

Publication Analysis

Top Keywords

electronic algorithm
8
prevention intraoperative
8
intraoperative awareness
8
intravenous agents
8
incorporates intravenous
8
novel electronic
4
algorithm detecting
4
detecting insufficient
4
insufficient anesthesia
4
anesthesia implications
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!