Background: The initial use of a 64-slice computed tomography (CT) scanner for obtaining quantitative perfusion data from a large ciliochoroidal melanoma, and correlation with 3T magnetic resonance imaging (MRI) dynamic enhancement and tumor histology.

Methods: The CT perfusion scan was performed using 80 kVp, 250 mA and 1-sec rotation time for 40 sec. The analysis was performed using commercial perfusion analysis software with a prototype 3-dimensional motion correction tool. Dynamic contrast-enhanced 3-Tesla MRI measured the kinetics of enhancement to estimate the vascular permeability. The time-dependent enhancement patterns were obtained using the average signal intensity using Functool analysis software. The involved globe was enucleated and microscopic evaluation of the tumor was performed.

Results: The perfusion parameters blood flow, blood volume and permeability surface area product in the affected eye determined by CT perfusion analysis were 118 ml/100 ml/min, 11.3 ml/100 ml and 48 ml/100 ml/min. Dynamic MRI enhancement showed maximal intensity increase of 111%. The neoplasm was a ciliochoroidal spindle cell melanoma which was mitotically active (13 mitoses/40 hpf). Vascular loops and arcades were present throughout the tumor. The patient developed metastases within 9 months of presentation.

Conclusion: Quantitative CT perfusion analysis of ocular tumors is feasible with motion correction software.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2693997PMC
http://dx.doi.org/10.2147/opth.s2071DOI Listing

Publication Analysis

Top Keywords

perfusion analysis
12
large ciliochoroidal
8
ciliochoroidal melanoma
8
mri dynamic
8
dynamic enhancement
8
quantitative perfusion
8
analysis software
8
motion correction
8
ml/100 ml/min
8
perfusion
7

Similar Publications

Unlabelled: Accurate estimation of the Lung Shunt Fraction (LSF) is a standard of care in yttrium-90 ( Y) radioembolization treatment planning to prevent excessive lung irradiation due to arterio-venous shunting in the liver. LSF is assessed using Tc macroaggregated albumin ( Tc-MAA) imaging, but this approach adds risk, complexity, and expense to the treatment planning. This study investigates the potential of Contrast-Enhanced Computed Tomography (CECT) as a non-invasive alternative for LSF estimation.

View Article and Find Full Text PDF

Cerebral perfusion alterations in healthy young adults due to two genetic risk factors of Alzheimer's disease: APOE and MAPT.

J Cereb Blood Flow Metab

January 2025

Sheffield Institute for Translational Neuroscience, Division of Neuroscience, School of Medicine and Population Heath, University of Sheffield, Sheffield, UK.

Functional brain changes such as altered cerebral blood flow occur long before the onset of clinical symptoms in Alzheimer's disease (AD) and other neurodegenerative disorders. While cerebral hypoperfusion occurs in established AD, middle-aged carriers of genetic risk factors for AD, including APOE ε4, display regional hyperperfusion due to hypothesised pleiotropic or compensatory effects, representing a possible early biomarker of AD and facilitating earlier AD diagnosis. However, it is not clear whether hyperperfusion already exists even earlier in life.

View Article and Find Full Text PDF

In patients with acute brain injury (ABI), optimizing cerebral perfusion parameters relies on multimodal monitoring. This include data from systemic monitoring-mean arterial pressure (MAP), arterial carbon dioxide tension (PaCO), arterial oxygen saturation (SaO), hemoglobin levels (Hb), and temperature-as well as neurological monitoring-intracranial pressure (ICP), cerebral perfusion pressure (CPP), and transcranial Doppler (TCD) velocities. We hypothesized that these parameters alone were not sufficient to assess the risk of cerebral ischemia.

View Article and Find Full Text PDF

Background: Pretreatment CT perfusion (CTP) marker relative cerebral blood volume (rCBV) < 42% lesion volume has recently shown to predict poor collateral status and poor 90-day functional outcome. However, there is a paucity of studies assessing its association with hemorrhagic transformation (HT). Here, we aim to assess the relationship between rCBV < 42% lesion volume with HT.

View Article and Find Full Text PDF

Plasma biomarkers have great potential in the screening, diagnosis, and monitoring of Alzheimer's disease (AD). However, findings on their associations with cerebral perfusion and structural changes are inconclusive. We examined both cross-sectional and longitudinal associations between plasma biomarkers and cerebral blood flow (CBF), gray matter (GM) volume, and white matter (WM) integrity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!