Aims: Right ventricular pacing increases the risk of persistent atrial fibrillation (AF) in the long term. The effects of right ventricular pacing on paroxysmal AF (PAF) are unknown. The aim was to examine the effect of right ventricular pacing on AF burden (AFB) in patients with symptomatic drug-resistant PAF. Pooled analysis of pacemaker-derived counters and AF diagnostic data from the Atrial Fibrillation Therapy (AFT) and Pacemaker Atrial Fibrillation Suppression (PAFS) randomized anti-AF pacemaker algorithm trials were used.

Methods And Results: Five hundred and fifty-four patients from the AFT (n = 372) and PAFS (n = 182) were studied. The individual percentages of pacing, Atrial Sense Ventricular Pace (ASVP), Atrial Pace Ventricular Pace (APVP), and Atrial Pace Ventricular Sense (APVS) as well as total ventricular pacing during synchronous rhythm (VPinSR, %) were examined for an effect on AFB. Three hundred and twenty-one (AFT, age 64 +/- 11, 55% male) and 79 (PAFS, age 71 +/- 8, 54% male) patients had complete data for analysis. Increased VPinSR was weakly associated with an increased AFB (effect size-10% VPinSR increased AFB by only 0.03%) in AFT (P = 0.04) but not PAFS (P = 0.98) or the pooled analysis (P = 0.95). None of the synchronous paced modalities (ASVP, APVP, APVS) significantly increased AFB compared with sinus rhythm (Atrial Sense Ventricular Sense) (P = ns).

Conclusion: No pacing modality, atrial or ventricular, had a significant effect on AFB. On the basis of these data, the detrimental effect of high-frequency right ventricular pacing on AFB in paced PAF patients, unlike with persistent AF, appears to be minimal in the short term.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eup218DOI Listing

Publication Analysis

Top Keywords

ventricular pacing
24
atrial fibrillation
16
increased afb
12
ventricular
11
atrial
9
high-frequency ventricular
8
pacing
8
pacing paroxysmal
8
pooled analysis
8
atrial sense
8

Similar Publications

The electrophysiological mechanisms underlying melatonin's actions and the electrophysiological consequences of superimposed therapeutic hypothermia (TH) in preventing cardiac ischemia-reperfusion (IR) injury-induced arrhythmias remain largely unknown. This study aimed to unveil these issues using acute IR-injured hearts. Rabbits were divided into heart failure (HF), HF+melatonin, control, and control+melatonin groups.

View Article and Find Full Text PDF

Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation-Feasibility, Procedural Caveats, Safety, and Follow-Up.

J Cardiovasc Electrophysiol

January 2025

Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.

Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.

Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.

View Article and Find Full Text PDF

Background: Protein-truncating mutations in the titin gene are associated with increased risk of atrial fibrillation. However, little is known about the underlying pathophysiology.

Methods: We identified a heterozygous titin truncating variant (TTNtv) in a patient with unexplained early onset atrial fibrillation and normal ventricular function.

View Article and Find Full Text PDF

Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.

Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!