A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Post-mortem examination of human fetuses: a comparison of whole-body high-field MRI at 9.4 T with conventional MRI and invasive autopsy. | LitMetric

AI Article Synopsis

  • High-field MRI at 9.4 T offers significantly better image quality and tissue contrast for evaluating small human fetuses compared to conventional MRI at 1.5 T.
  • A study involving 18 fetuses showed that all detected abnormalities via invasive autopsy corresponded with findings from high-field MRI, while 78% of cases were missed using conventional MRI.
  • High-field MRI shows promise as a minimally invasive alternative for perinatal autopsies, effectively providing good tissue characterization even for very small fetuses.

Article Abstract

Background: Conventional whole-body MRI at 1.5 T does not provide adequate image quality of small fetuses, thus reducing its potential for use as an alternative to invasive autopsy. High-field whole-body MRI at 9.4 T provides good images of small animals. We therefore compared the diagnostic usefulness of high-field MRI with conventional MRI for post-mortem examination of human fetuses.

Methods: We did whole-body MRI at 9.4 T and 1.5 T on 18 fetuses of less than 22 weeks' gestation, using three-dimensional T(2)-weighted fast-spin echo sequences, before doing invasive autopsy. Images obtained with MRI for each system were compared with the findings of invasive autopsy in a blinded manner. Tissue contrast of 14 different regions was compared on 1.5 T and 9.4 T images that were provided by paediatric radiologists separately and in a random order, and image quality was scored on a four-point scale. The primary endpoint was diagnostic accuracy.

Findings: Spatial resolution, tissue contrast, and image quality of all organ systems were much better with high-field MRI than with conventional MRI. All structural abnormalities that were detected with invasive autopsy and internal examination of visceral organs were also detected with high-field MRI, whereas conventional MRI was not diagnostically useful in 14 (78%) cases.

Interpretation: Whole-body high-field MRI is a feasible option for post-mortem examination of human fetuses, and can provide good tissue characterisation even in small fetuses (5 g). The use of MRI at 9.4 T might be helpful in the development of a minimally invasive perinatal autopsy system.

Funding: Department of Health Policy Research Programme, British Heart Foundation, National Institute of Health Research, Higher Education Funding Council for England, Biotechnology and Biological Sciences Research Council, Engineering and Physical Sciences Research Council, Great Ormond Street Hospital, University College London (UCL) Institute of Child Health, UCL Hospital, and UCL.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0140-6736(09)60913-2DOI Listing

Publication Analysis

Top Keywords

high-field mri
20
invasive autopsy
20
mri conventional
16
conventional mri
16
mri
14
post-mortem examination
12
examination human
12
whole-body mri
12
image quality
12
human fetuses
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!