Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Withdrawal of the support for the REMEDi HS drug profiling system has necessitated its replacement within our laboratories with an alternative broad toxicological screening technique. To this end, a novel method, based on ultra-performance liquid chromatography (UPLC) and time-of-flight (TOF) mass spectrometry, was developed for the routine analysis of urine samples. Identification was achieved by comparison of acquired data to libraries containing more than 300 common drugs and metabolites, and was based on a combination of retention time, exact mass and fragmentation patterns. Validation data for the method is presented and comprised an evaluation of the following parameters: precision; transferability of the methodology between the six collaborating laboratories; specificity; extraction recovery and stability of processed samples; matrix effects and sensitivity. This paper presents the benefits of supplementary fragmentation data with particular regard to increasing specificity and confidence of identification and its usefulness with overdosed samples. The utility of the method was assessed by the parallel analysis of 30 authentic urine samples using the REMEDi HS and UPLC-TOF. The latter provided enhanced detection, leading to the identification of twice as many drugs. Furthermore it did not miss any compounds that were identified by REMEDi HS. The UPLC-TOF findings were further verified by a combination of data from three other conventional screening techniques, i.e., GC-MS, HPLC-DAD and UPLC-MS/MS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2009.06.068 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!