Object: Microelectrode recording (MER) and macrostimulation (test stimulation) are used to refine the optimal deep brain stimulation (DBS) lead placement within the operative setting. It is well known that there can be a microlesion effect with microelectrode trajectories and DBS insertion. The aim of this study was to determine the impact of intraoperative MER and lead placement on tremor severity in a cohort of patients with essential tremor.
Methods: Consecutive patients with essential tremor undergoing unilateral DBS (ventral intermediate nucleus stimulation) for medication-refractory tremor were evaluated. Tremor severity was measured at 5 time points utilizing a modified Tremor Rating Scale: 1) immediately before MER; 2) immediately after MER; 3) immediately after lead implantation; 4) 6 months after DBS implantation in the off-DBS condition; and 5) 6 months after implantation in the on-DBS condition. To investigate the impact of the MER and DBS lead placement, Wilcoxon signed-rank tests were applied to test changes in tremor severity scores over the surgical course. In addition, a generalized linear mixed model including factors that potentially influenced the impact of the microlesion was also used for analysis.
Results: Nineteen patients were evaluated. Improvement was noted in the total modified Tremor Rating Scale, postural, and action tremor scores (p < 0.05) as a result of MER and DBS lead placement. The improvements observed following lead placement were similar in magnitude to what was observed in the chronically programmed clinic setting parameters at 6 months after lead implantation. Improvement in tremor severity was maintained over time even in the off-DBS condition at 6 months, which was supportive of a prolonged microlesion effect. The number of macrostimulation passes, the number of MER passes, and disease duration were not related to the change in tremor severity score over time.
Conclusions: Immediate improvement in postural and intention tremors may result from MER and DBS lead placement in patients undergoing DBS for essential tremor. This improvement could be a predictor of successful DBS lead placement at 6 months. Clinicians rating patients in the operating room should be aware of these effects and should consider using rating scales before and after lead placement to take these effects into account when evaluating outcome in and out of the operating room.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3171/2009.7.JNS09150 | DOI Listing |
J Electrocardiol
January 2025
Victorian Heart Institute, Monash University, Clayton, VIC, Australia; Victorian Heart Hospital, Clayton, VIC, Australia. Electronic address:
Introduction: This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).
Methods: We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation.
Background: Placement of right precordial leads in higher intercostal spaces (EEP-ECG) improves the detection of Brugada Syndrome (BrS). Given the potential difficulty of lead placement and the transient nature of BrS ECG patterns, we developed a model to predict EEP-ECG from a standard 12‑lead ECG.
Objective: To create and validate a model that derives EEP-ECG leads from a standard 12‑lead ECG.
Antibiotics (Basel)
January 2025
Unit II, Department of Infectious Diseases, Luigi Sacco Hospital, ASST Fatebenefratelli Sacco, 20157 Milan, Italy.
: Vascular access device (VAD)-associated infections, including catheter-related (CRBSI) and catheter-associated bloodstream infections (CABSI), present significant challenges in patient care. While multidisciplinary VAD teams (VATs) are equipped with protocols for managing these infections, adherence to these guidelines in real-life practice is inconsistent. This study aims to evaluate the alignment between actual VAD infection management practices and VAT-recommended protocols.
View Article and Find Full Text PDFMed Image Anal
January 2025
Department of Engineering Science, University of Oxford, Oxford, UK.
Cardiac digital twins (CDTs) offer personalized in-silico cardiac representations for the inference of multi-scale properties tied to cardiac mechanisms. The creation of CDTs requires precise information about the electrode position on the torso, especially for the personalized electrocardiogram (ECG) calibration. However, current studies commonly rely on additional acquisition of torso imaging and manual/semi-automatic methods for ECG electrode localization.
View Article and Find Full Text PDFJ Urol
January 2025
Department of Population Health, NYU Grossman School of Medicine, New York, New York.
Purpose: We aimed to determine whether implementation of clinical decision support (CDS) tool integrated into the electronic health record (EHR) of a multi-site academic medical center increased the proportion of patients with American Urological Association (AUA) "high risk" microscopic hematuria (MH) who receive guideline concordant evaluations.
Materials And Methods: We conducted a two-arm cluster randomized quality improvement project in which 202 ambulatory sites from a large health system were randomized to either have their physicians receive at time of test results an automated CDS alert for patients with 'high-risk' MH with associated recommendations for imaging and cystoscopy (intervention) or usual care (control). Primary outcome was met if a patient underwent both imaging and cystoscopy within 180 days from MH result.