Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A membrane-based electrochemical nanobiosensor sensitive toward whole viral particles is fabricated by forming a submicrometer thick nanoporous alumina membrane over a platinum disk electrode. Antibody probe molecules are physically adsorbed onto the walls of the membrane nanochannels. The sensing signal is based on the monitoring of the electrode's Faradaic current response toward ferrocenemethanol, which is extremely sensitive to the formation of immunocomplex within the nanoporous membrane. This nanobiosensor is demonstrated for the sensing of West Nile virus protein domain III (WNV-DIII) and the inactivated West Nile viral particle, using anti-WNV-DIII immunoglobulin M (IgM) as the biorecognition probe. The detection of the viral protein and the particle are logarithmically linear up to 53 pg mL(-1) (R(2) = 0.99) and 50 viral particles per 100 mL (R(2) = 0.93) in pH 7, with extremely low detection limits of 4 pg mL(-1) and ca. 2 viral particles per 100 mL, comparable to sensitivities of polymerase chain reaction techniques. The relative standard deviation (RSD) of whole viral particle detection in whole blood serum is 6.9%. In addition, the simple nanobiosensor construction procedure, minimal sample preparation, and short detection time of 30 min are highly attractive properties and demonstrate that the detection of a wide range of proteins and viruses can be achieved.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac900761a | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!