Objective: To study the effect of all-coated long stem prosthesis associated with allograft in revision total hip replacement (THR).
Methods: From January 1997 to January 2004, 20 patients with non-infectious loosened implant after primary THR were treated. There were 12 males and 8 females with a mean age of 65 years (58-77 years). The average period between primary THR and revision THR was 12 years (3-18 years). According to classification of Paprosky, there were 10 cases of type II, 6 cases of type IIIA, 3 cases of type IIIB and 1 case of type IV. All-coated long stem prosthesis was used in all cases. Impacting bone grafting was done in 12 cases and impacting bone grafting associated with cortical strut grafting in 8 cases. The mean amount of morselized bone was 20 g (5-35 g), the length of cortical bone was 10-22 cm.
Results: All the incisions got healing by first intension. All patients were followed up for an average period of 36 months (16-48 months). Dislocation occurred at 5 days after operation and was cured with closed reduction and traction in 1 case. There was significant difference (P < 0.05) in the mean Harris score between preoperation (50.0 +/- 2.3) and postoperation (90.0 +/- 2.5). The X-ray checking showed that continuous radiolucent line of 3 mm occurred in 1 case, prosthesis subsidence of 5 mm and 7 mm in 2 cases and that no bone absorption was observed. Seven cases of cortical bone grafting union was achieved within 3 years except 1 case of cortical bone un-union.
Conclusion: It can obtained the initial stabilization of prosthesis to use all-coated long stem prosthesis associated with allograft in revision THR to treat femur bone defect after THR. The short-term effects of the clinical and X-ray checking are satisfactory, but future effect is to be observed.
Download full-text PDF |
Source |
---|
J Artif Organs
January 2025
Department for Cardiac, Thoracic and Cardiovascular Surgery, University Hospital Regensburg, Regensburg, Germany.
Neutrophil extracellular traps (NETs) were detected in blood samples and in cellular deposits of oxygenator membranes during extracorporeal membrane oxygenation (ECMO) therapy and may be responsible for thrombogenesis. The aim was to evaluate the effect of the base material of gas fiber (GF, polymethylpentene) and heat exchange (HE) membranes and different antithrombogenic coatings on isolated granulocytes from healthy volunteers under static culture conditions. Contact of granulocytes with membranes from different ECMO oxygenators (with different surface coatings) and uncoated-GFs allowed detection of adherent cells and NETotic nuclear structures (normal, swollen, ruptured) using nuclear staining.
View Article and Find Full Text PDFDent Mater
August 2024
School of Dentistry, Institute of Clinical Sciences, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom. Electronic address:
Introduction: Peri-implantitis is an inflammatory process around dental implants that is characterised by bone loss that may jeopardize the long-term survival of osseo integrated dental implants. The aim of this study was to create a surface coating on titanium abutments that possesses cellular adhesion and anti-microbial properties as a post-implant placement strategy for patients at risk of peri-implantitis.
Materials And Methodsmethods: Titanium alloy Grade V stubs were coated with gold particles and then subjected to ceramic conversion treatment (CCT) at 620 °C for 3, 8 and 80 h.
Beijing Da Xue Xue Bao Yi Xue Ban
August 2022
Department of Urology, Peking University People's Hospital, Beijing 100044, China.
Objective: To comprehensively evaluate the long-term efficacy and safety of coated metal stent implantation for ureteroscopic lithotripsy related refractory ureteral stricture (URL-rUS).
Methods: Electronic medical records of 30 patients (31 affected renal units) receiving coated metal stent implantation for URL-rUS from Sept. 2018 to Aug.
Acta Bioeng Biomech
June 2023
Silesian University of Technology, Faculty of Biomedical Engineering, Department of Biomaterials and Medical Devices Engineering, Zabrze, Poland.
The constantly growing need for the use of implants in osteotomy is mainly due to the aging population and the need for long-term use of this type of biomaterials. Improving implant materials requires the selection of appropriate functional properties. Currently used titanium (Ti) alloys, such as Ti6Al4V and Ti6Al7Nb, are being replaced by materials with better biocompatibility, such as vanadium (V) or niobium (Nb), allowing for creation of the so-called new generation alloys.
View Article and Find Full Text PDFInt J Biol Macromol
January 2022
Vinča Institute of Nuclear Sciences - National Institute of the Republic of Serbia, University of Belgrade, Belgrade, Serbia. Electronic address:
Aqueous colloids, consisting of 15-30 nm-sized silver nanoparticles (Ag NPs), were prepared using the reducing and stabilizing abilities of glucose, sucrose, and dextran. The long-term stability of coated Ag NPs increases from glucose over sucrose to dextran, i.e.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!