During laparoscopic grasping, tissue damage may occur due to use of excessive grasp forces and tissue slippage, whereas in barehanded grasping, humans control their grasp to prevent slippage and use of excessive force (safe grasp). This study investigates the differences in grasp control during barehanded and laparoscopic lifts. Ten novices performed lifts in order to compare pinch forces under four conditions: barehanded; using tweezers; a low-efficient grasper; and a high-efficient grasper. Results showed that participants increased their pinch force significantly later during a barehanded lift (at a pull-force level of 2.63 N) than when lifting laparoscopically (from pull-force levels of 0.77 to 1.08 N). In barehanded lifts all participants could accomplish a safe grasp, whereas in laparoscopic lifts excessive force (up to 7.9 N) and slippage (up to 38% of the trials) occurred frequently. For novices, it can be concluded that force feedback (additional to the hand-tool interface), as in skin-tissue contact, is a prerequisite to maintain a safe grasp. Much is known about grasp control during barehanded object manipulation, especially the control of pinch forces to changing loading, whereas little is known about force perception and grasp control during tool usage. This knowledge is a prerequisite for the ergonomic design of tools that are used to manipulate objects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/00140130902912803 | DOI Listing |
Sci Rep
January 2025
Zhongyuan University of Technology, Zhengzhou, 450007, China.
This paper studies the practical prescribed-time control problem for dual-arm robots handling an object with output constraints. Firstly, by utilizing the property that the sum of internal forces in the grasping space is zero, the system model is obtained and decomposed into the contact force model and free motion model, which are orthogonal to each other. Furthermore, by combining the performance function and constraint function, the original system tracking error is transformed to a new one, whose boundedness can ensure that the original system variable converges to the predetermined range within the specified time.
View Article and Find Full Text PDFJ Biomech
January 2025
The Joint Department of Biomedical Engineering, the University of North Carolina at Chapel Hill, Chapel Hill, NC, United States; North Carolina State University, Raleigh, NC, United States.
Throughout childhood growth and development, both the nervous and the musculoskeletal systems undergo rapid change. The goal of this study was to examine the impact of growth-related changes in skeletal size and muscle strength on the neural control of finger force generation. By modifying an existing OpenSim hand model in accordance with pediatric anthropometric data, we created 10 distinct models representing males and females at each year of development from 6 to 10 years old.
View Article and Find Full Text PDFJ Integr Neurosci
January 2025
Department of Ophthalmology, University Hospital of Udine, 33100 Udine, Italy.
The complicated neurological syndrome known as multiple sclerosis (MS) is typified by demyelination, inflammation, and neurodegeneration in the central nervous system (CNS). Managing this crippling illness requires an understanding of the complex interactions between neurophysiological systems, diagnostic techniques, and therapeutic methods. A complex series of processes, including immunological dysregulation, inflammation, and neurodegeneration, are involved in the pathogenesis of MS.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Department of Mechanical and Intelligent Systems Engineering, The University of Electro-Communications, Tokyo 1828585, Japan.
Recently, aerial manipulations are becoming more and more important for the practical applications of unmanned aerial vehicles (UAV) to choose, transport, and place objects in global space. In this paper, an aerial manipulation system consisting of a UAV, two onboard cameras, and a multi-fingered robotic hand with proximity sensors is developed. To achieve self-contained autonomous navigation to a targeted object, onboard tracking and depth cameras are used to detect the targeted object and to control the UAV to reach the target object, even in a Global Positioning System-denied environment.
View Article and Find Full Text PDFLife (Basel)
January 2025
Department of Hand, Plastic and Aesthetic Surgery, LMU Klinikum, Ziemssenstraße 5, 80336 Munich, Germany.
Background: Dupuytren's disease (DD) is a systemic connective tissue disorder of the palm, predominantly affecting men of Northern European or Caucasian origin over 55. In addition to conventional surgery, Dupuytren's contracture can be treated in a minimally invasive way by injecting bacterial collagenase into the cord. However, studies on the long-term success rate when compared to the gold standard, surgical limited fasciectomy, are limited.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!