Background Context: Biomechanical studies have demonstrated increased motion in motion segments adjacent to instrumentation or arthrodesis. The effects of different configurations of hook and pedicle screw instrumentation on the biomechanical behaviors of adjacent segments have not been well documented.

Purpose: To compare the effect of three different fusion constructs on adjacent segment motion proximal to lumbar arthrodesis.

Methods: Seven human cadaver lumbar spines were tested in the following conditions: 1) intact; 2) L4-L5-simulated circumferential fusion (CF); 3) L4-L5-simulated fusion extended to L3 with pedicle screws; and 4) L4-L5-simulated fusion extended to L3 with sublaminar hooks. Rotation data at L2-L3, L3-L4, and L4-L5 were analyzed using both load limit control (+/-7.5N.m) and displacement limit control (truncated to the greatest common angular motion of the segments for each specimen).

Results: Both the L3-L4 and L2-L3 motion segments above the L4-L5-simulated CF had significantly increased motion in all loading planes compared with the intact spine, but no significant differences were found between L3-L4 and L2-L3 motion. When the L3-L4 segment was stabilized with pedicle screws, its motion was significantly smaller in flexion, lateral bending, and axial rotation than when stabilized with sublaminar hooks. At the same time, L2-L3 motion was significantly larger in flexion, lateral bending, and axial rotation in the pedicle screw model compared with the sublaminar hook construct.

Conclusions: The use of sublaminar hooks to stabilize the motion segment above a circumferential lumbar fusion reduced motion at the next cephalad segment compared with a similar construct using pedicle screws. The semiconstrained hook enhancement may be considered if a patient is at a risk of adjacent segment disorders.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2009.06.019DOI Listing

Publication Analysis

Top Keywords

motion segments
12
pedicle screws
12
sublaminar hooks
12
l2-l3 motion
12
motion
11
increased motion
8
pedicle screw
8
adjacent segment
8
l4-l5-simulated fusion
8
fusion extended
8

Similar Publications

Multidimensional morphological analysis of live sperm based on multiple-target tracking.

Comput Struct Biotechnol J

December 2024

Department of Assisted Reproduction, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, China.

Manual semen evaluation methods are subjective and time-consuming. In this study, a deep learning algorithmic framework was designed to enable non-invasive multidimensional morphological analysis of live sperm in motion, improve current clinical sperm morphology testing methods, and significantly contribute to the advancement of assisted reproductive technologies. We improved the FairMOT tracking algorithm by incorporating the distance and angle of the same sperm head movement in adjacent frames, as well as the head target detection frame IOU value, into the cost function of the Hungarian matching algorithm.

View Article and Find Full Text PDF

Introduction Thoracolumbar fractures, particularly burst fractures, represent a significant health concern due to their prevalence and functional impact. This study evaluates the efficacy of short-segment posterior fixation with intermediate screw instrumentation in treating unstable thoracolumbar fractures. Methods A prospective study was conducted from July 2022 to December 2023, including 26 patients with traumatic thoracolumbar fractures.

View Article and Find Full Text PDF

Keyhole decompression surgery for holospinal epidural abscess: a novel approach for spinal stability preservation.

Eur Spine J

January 2025

Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Japan.

Purpose: Spinal epidural abscesses are rare yet serious conditions, often necessitating emergency surgical intervention. Holospinal epidural abscesses (HEA) extending from the cervical to the lumbosacral spine are even rarer and present significant challenges in management. This report aims to describe a case of HEA with both ventrally-located cervical and dorsally-located thoracolumbar epidural abscesses treated with a combination of anterior keyhole decompression and posterior skip decompression surgeries.

View Article and Find Full Text PDF

This study compares clinical and radiological outcomes of open microscopic posterior cervical foraminotomy (PCF) and biportal endoscopic spine surgery (BESS) PCF in multi-level cases. While BESS PCF is effective in single-level surgeries, its role in multi-level procedures remains unclear. : This retrospective cohort study included 60 patients treated for cervical radiculopathy from 2016 to 2023, divided into two groups, open microscopic PCF (Group M, = 30) and BESS PCF (Group B, = 30).

View Article and Find Full Text PDF

The American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values (TLVs) for lifting provides risk zones for assessing two-handed lifting tasks. This paper describes two computational models for identifying the lifting risk zones using gyroscope information from five inertial measurement units (IMUs) attached to the lifter. Two models were developed: (1) the ratio model using body segment length ratios of the forearm, upper arm, trunk, thigh, and calf segments, and (2) the ratio + length model using actual measurements of the body segments in the ratio model.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!