This case report describes a newly developed prosthetic arm for a world class trans-humeral amputee cyclist. The proposed solution consists of a new prosthetic kit that was designed to meet requirements of weight, freedom of movement and precise positioning for the disciplines of time-trial, pursuit, road and team sprint. The kit is made of different attachments that can be changed depending on the event the athlete is competing in. The prosthesis is composed of an extended socket made of composite materials, an arm made of aluminum tubes, a universal joint for the junction with the handlebars and different attachments for each bicycle. The system's weight is kept to a minimum using finite element analysis and careful material selection. The universal joint provides the angular degrees of freedom required to allow the athlete to stand up while pedaling, a freedom of movement lost since amputation. In this case report, the athlete's needs are presented and followed by the design of the product using Finite Element modeling. Results are then presented and discussed. This prosthetic kit was used by the athlete for the 2008 Paralympics games in Beijing.

Download full-text PDF

Source
http://dx.doi.org/10.1080/03093640903045198DOI Listing

Publication Analysis

Top Keywords

prosthetic kit
12
case report
8
freedom movement
8
universal joint
8
finite element
8
design development
4
development arm
4
prosthetic
4
arm prosthetic
4
kit
4

Similar Publications

A comparative study between condensed polytetrafluoroethylene hernia mesh versus other composite meshes in Endo-laparoscopic ventral hernia repair.

Asian J Surg

November 2024

Division of Minimally Invasive Surgery, Department of Surgery, National University Hospital, Singapore; Department of Surgery, National University of Singapore, Singapore.

Introduction: Laparoscopic ventral hernia mesh repair (LVHR) is gaining popularity possibly due to reduced complications, reduced hospital stay, early return to work and better cosmesis. In intra-peritoneal onlay method (IPOM) a dual layer composite mesh with an absorbable barrier on the visceral surface is used for minimising bowel adhesions. Three most popular prosthetic mesh scaffolds are polypropylene (PP), polyester and expanded polytetrafluoroethylene (ePTFE).

View Article and Find Full Text PDF

Objectives: Alzheimer's disease (AD), a brain disorder, is the leading cause of dementia among older adults. Taurine, an amino acid abundantly present in the brain, and shows potential neuroprotective properties. Therefore, we investigated the effects of taurine on Matrix Metalloproteinase-9 (MMP-9) levels and the expression changes of miRNA-21 and miRNA-146a in the SH-SY5Y cell line.

View Article and Find Full Text PDF

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit.

View Article and Find Full Text PDF

Non-surgical Endodontic Management of Multiple Mishaps: A Case Report.

Cureus

April 2024

Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Majmaah University, Al-Majmaah, SAU.

The description of non-surgical retreatment is to eliminate all previous filling materials and correct any mishaps. An adequate understanding of root and canal morphology is a fundamental requirement for obtaining a favorable outcome in endodontic treatment. The endodontic diagnosis was previously treated through therapy with symptomatic apical periodontitis.

View Article and Find Full Text PDF

This project investigates if third-generation genomic sequencing can be used to identify the species of bacteria causing prosthetic joint infections (PJIs) at the time of revision surgery. Samples of prosthetic fluid were taken during revision surgery from patients with known PJIs. Samples from revision surgeries from non-infected patients acted as negative controls.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!