Prevention of dislocation in total hip revision surgery using a dual mobility design.

Orthop Traumatol Surg Res

EA 4338, laboratoire de physiologie de l'exercice, Orthopedic and Trauma Surgery Department, centre hospitalier et universitaire de Saint-Etienne, 42055 Saint-Etienne cedex 2, France.

Published: October 2009

Background: Postoperative dislocation is the commonest complication following revision total hip arthroplasty (THA). HYPOTHESIS AND TYPE OF STUDY: Dual mobility cups are supposed to reduce the risk of THA instability. The present retrospective study tested this hypothesis on revision THAs and also, assessed this design contribution to acetabular fixation longevity.

Materials And Methods: The series was homogeneous and continuous, comprising a total of 163 revision THAs: 110 of them were bipolar revisions and 53 were restricted to the acetabular component exchange. Mean patient age was 68.7 years (range: 34-92 years). Novae (SERF, Décines) dual mobility cups were used in all cases: 110 cementless cups were used and 53 cups were cemented in a Kerboull reinforcement ring due to severe acetabular bone loss.

Results: Mean patients' follow-up (FU) was 60.4 + or - 17.6 months. There were six early dislocations (which were reduced without additional surgery and remained recurrence-free) and two cases of acetabular loosening. The total postoperative dislocation rate at the end of follow-up was 3.7% and the 7-year cup survivorship rate was 96.1% (95% CI: 92.8-99.2%). In revision for aseptic loosening, the instability rate was 2.9%; in the higher instability risk groups (i.e., revision for infection and or recurrent instability) the dislocation rate was respectively 9% and 0%.

Discussion: Dual mobility cups provided a dislocation rate of only 3.7% in revision THA, comparable to the one reported with standard implants for primary THA. This kind of cup design is especially suited to deal with high instability risk revision cases, where constrained components are generally recommended. It can also be indicated in cases of aseptic loosening, where it resulted in a 2.9% dislocation rate and only two impending failures of fixation. In terms of mechanical failure rate, these numbers compare well to the ones pertaining to tripolar and constrained implants. These later alternatives remain possible options but are not fully efficient in terms of long-term stability and fixation longevity. LEVEL OF STUDY: Level IV, retrospective or records-based.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2009.04.016DOI Listing

Publication Analysis

Top Keywords

dual mobility
16
dislocation rate
16
mobility cups
12
total hip
8
revision
8
postoperative dislocation
8
revision thas
8
aseptic loosening
8
instability risk
8
rate
7

Similar Publications

Scapho-metacarpal dual mobility prosthesis for TMC-1 joint salvage: technical insights.

Arch Orthop Trauma Surg

January 2025

BG Klinikum Unfallkrankenhaus Berlin, Department of Hand-, Replantation- and Microsurgery and Chair of Hand-, Replantation- and Microsurgery, Charité Universitätsmedizin Berlin, Berlin, Germany.

Introduction: Rhizarthrosis, or osteoarthritis of the trapeziometacarpal joint, predominantly affects women over 50, with up to 30% experiencing some degree of arthritis in this joint. Traditional surgical approaches, such as trapeziectomy with ligament reconstruction, can result in some patients in persistent pain or limited functionality. TMC ball-in-socket arthroplasty, with a cup placed in the distal scaphoid, offers a promising alternative to traditional arthrodesis or resection-suspension arthroplasty.

View Article and Find Full Text PDF

Total joint arthroplasty of the thumb CMC joint.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedics and Traumatology, Second Faculty of Medicine, Charles University in Prague and University Hospital Motol, Prague, Czech Republic.

Purpose Of The Study: Rhizarthrosis-osteoarthritis of the thumb carpometacarpal (CMC) joint is usually a primary idiopathic disease. Total joint arthroplasty (TJA) is one of the surgical treatment options for symptomatic advanced thumb CMC arthritis. This retrospective study aims to evaluate the mid-term functional and radiological results of TJA with the minimum follow-up period of 3 years after the surgery.

View Article and Find Full Text PDF

Background: Dual mobility (DM) implants in total hip arthroplasty provide excellent range of motion with low dislocation rates. A complication of this design is intraprosthetic dislocation (IPD), where the polyethylene (PE) liner dissociates from the femoral head. In older designs, IPD occurred due to a small head size and late PE wear with head-capture-mechanism failure.

View Article and Find Full Text PDF

Background: Bicondylar tibial plateau fractures are often associated with significant soft tissue compromise making operative treatment challenging. Dual plating through a two-incision approach following temporary external fixation has been shown to improve complication rates although deep infection rates remain high.The objective was to evaluate early outcomes following a novel technique of percutaneous application of the medial plate superficial to the pes anserinus tendons.

View Article and Find Full Text PDF

Background: Dislocation remains a common complication following total hip arthroplasty (THA). Previous literature has shown that the femoral head-to-neck ratio is essential in hip motion, function, and stability. While large femoral heads and dual mobility bearings have been developed to improve stability, it remains unknown if the ratio between femoral head size to acetabular cup size also plays a role in stability.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!