Total hip arthroplasty (THA) significantly improves the quality of life in majority of patients with severe osteoarthritis. However, long-term outcomes of THAs are compromised by aseptic loosening and periprosthetic osteolysis which needs revision surgery. Both of these are causally linked to a prosthetic wear deliberated from the prosthetic articulating surfaces. As a result, there is a need to measure the mode and magnitude of wear. The paper evaluates three optical methods proposed for construction of a device for the non-contact prosthetic wear measurement. Of them, the scanning profilometry achieved promising combination of accuracy and repeatability. Simultaneously, it is time efficient to enable the development of a sensor for wear measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1364/oe.17.012723DOI Listing

Publication Analysis

Top Keywords

prosthetic wear
12
optical methods
8
total hip
8
hip arthroplasty
8
wear measurement
8
wear
5
methods measurement
4
prosthetic
4
measurement prosthetic
4
wear total
4

Similar Publications

The study aimed to validate the diagnostic system proposed by the Standardized Tool for the Assessment of Bruxism (STAB) by correlating the results obtained based on questionnaire and non-instrumental and instrumental tools. The study had three stages (questionnaire, clinical examination, and electromyographic study). The subjects completed a questionnaire and clinical exam.

View Article and Find Full Text PDF

Measurement of volumetric wear of printed polymer resin and milled polymer infused ceramic network definitive restorative materials.

J Prosthet Dent

January 2025

Associate Professor and Director of Student Research, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, OH. Electronic address:

Statement Of Problem: Currently there is no regulatory requirement or international standard for the wear resistance of dental materials and therefore no need to test prior to market launch.

Purpose: The purpose of this in vitro study was to evaluate and compare the total volumetric wear characteristics of milled polymer infiltrated ceramic network (MPICN) and printed polymer resin (PPR) as substrates opposing five antagonists, human enamel (EN), lithium disilicate (LD), zirconia (ZR), MPICN, and PPR, and to evaluate and compare the volumetric wear of these same materials as antagonists.

Material And Methods: Ten of each antagonist for a total of 50 EN, LD (IPS e.

View Article and Find Full Text PDF

Hydroxyapatite (HAP) nano-coatings on titanium alloys (for example, Ti6Al4V) have been used for prosthetic orthopedic implants in recent decades due to their osseointegration, bioactivity, and biocompatibility. HAP is brittle with low mechanical strength and poor adhesion on metallic surfaces, which limits its durability and bioactivity. Surface modification techniques have alleviated the imperfection of biomaterials by coating the substrate.

View Article and Find Full Text PDF

The One-step No-prep technique for non-invasive full-mouth rehabilitation of worn dentition using PICN CAD-CAM restorations: Up to 9-year results from a prospective and retrospective clinical study.

Dent Mater

January 2025

Dental Biomaterials Research Unit (d-BRU), Institute of Dentistry, University of Liège (ULiège), Liège, Belgium; Department of Fixed Prosthodontics, Institute of Dentistry, University of Liège Hospital (CHU), Liège, Belgium. Electronic address:

Objectives: To report up to 9-year results of a prospective and retrospective study on non-invasive full-mouth rehabilitation of worn dentition with PICN CAD-CAM restorations using the One-Step No-Prep technique. The secondary objective is to evaluate the influence of restoration thickness on fracture of restorations.

Methods: A total of 580 Vita Enamic restorations (218 anterior and 362 posterior; 260 monoblock (MO) and 320 multiColor (MC)) in 24 patients were clinically evaluated once a year (up 9 months to 9 years) according to FDI criteria.

View Article and Find Full Text PDF

Patient: A 26-year-old man with localized tooth wear and demand for aesthetic rehabilitation of the anterior teeth presented to our department. The patient reported excessive consumption of energy drinks. Furthermore, multiple trauma and tooth fractures have occurred in the past.

View Article and Find Full Text PDF