Low bone mass is highly prevalent among patients receiving endosseous implants. In turn, the implantation prognosis in low-density skeletal sites is poor. However, little is known about the mechanostructural determinants of implant anchorage. Using metabolic manipulations that lead to low bone density and to its rescue, we show here that anchorage is critically dependent on the peri-implant bone (PIB). Titanium implants were inserted horizontally into the proximal tibial metaphysis of adult rats 6 weeks after orchiectomy (ORX) or sham ORX. Systemic intermittent administration of human parathyroid hormone (1-34) [iahPTH(1-34)] or vehicle commenced immediately thereafter for 6 weeks. The bone-implant apparatus was then subjected to image-guided failure assessment, which assesses biomechanical properties and microstructural deformation concomitantly. Anchorage failure occurred mainly in PIB trabeculae, 0.5 to 1.0 mm away from the implant. Mechanically, the anchorage performed poorly in ORX-induced low-density bone, attributable mainly to decreased trabecular number. iahPTH(1-34) rescued the PIB density and implant mechanical function by augmenting trabecular thickness (Tb.Th). However, implant biomechanical properties in low-density bone were relatively insensitive to implant surface treatment that affected only the osseointegration (%bone-implant contact). These results support a model wherein anchorage failure involves buckling of the weakest trabecular struts followed by sequential failure of the stronger trabeculae. Treatment with iahPTH(1-34) induced thicker struts, which were able to delay and even prevent failure of individual elements, thus implicating trabecular thickness as a prime target for enhancing implant anchorage by systemic bone anabolic therapy.

Download full-text PDF

Source
http://dx.doi.org/10.1359/jbmr.090808DOI Listing

Publication Analysis

Top Keywords

implant anchorage
12
anchorage critically
8
critically dependent
8
mechanostructural determinants
8
peri-implant bone
8
low bone
8
biomechanical properties
8
anchorage failure
8
low-density bone
8
trabecular thickness
8

Similar Publications

Chronic implantable flexible serpentine probe reveals impaired spatial coding of place cells in epilepsy.

Natl Sci Rev

February 2025

State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.

The development of minimally invasive and reliable electrode probes for neural signal recording is crucial for advancing neuroscience and treating major brain disorders. Flexible neural probes offer superior long-term recording capabilities over traditional rigid probes. This study introduces a parylene-based serpentine electrode probe for stable, long-term neural monitoring.

View Article and Find Full Text PDF

Prosthetic rehabilitation of a hemimaxillectomy patient using a zygomatic - Corticobasal® implant- supported reconstructive prosthesis: A case report.

Int J Surg Case Rep

January 2025

Department of Prosthodontics, RAK College of Dental Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah, United Arab Emirates. Electronic address:

Introduction: Rehabilitation of patients with hemimaxillectomy presents a challenge. This case report describes the successful use of zygomatic Corticobasal® implant- supported reconstructed prosthesis.

Clinical Case Presentation: A 20-year-old female patient presented to the clinic following hemimaxillectomy with soft tissue approximation one year ago.

View Article and Find Full Text PDF

We aim to assess and contrast the mechanical stability of two mini-implant designs, featuring larger diameters and shorter lengths, for orthodontic anchorage against a conventional group of implants.

View Article and Find Full Text PDF

: Achieving ideal anchorage is crucial in orthodontics for controlled tooth movement. Miniscrews (MSs) have improved skeletal anchorage, but freehand placement poses risks like root damage and limited precision. Guided techniques, including radiographic guides and computer-assisted methods (static [sCAS] and dynamic [dCAS]), were developed to enhance accuracy and safety.

View Article and Find Full Text PDF

Superior effect of mini-implant anchorage in the treatment of skeletal class II malocclusion.

J Orthod Sci

November 2024

Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Binh Thanh District, Ho Chi Minh City, Vietnam.

Objectives: To evaluate the effectiveness of mini-implant (MI) anchorage versus conventional anchorage for the treatment of skeletal class II malocclusion.

Materials And Methods: The study was conducted on 64 patients with skeletal class II malocclusion. The patients were divided into two groups: 1) 32 patients underwent conventional anchorage, and 2) 32 patients underwent MI anchorage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!