The build-up of intensity-as a function of the number, n(rcpl), of POST-C7 elements used for the excitation and reconversion of double-quantum (DQ) coherence (DQC)-is analysed for the fifteen distinct DQ correlation peaks that are observed experimentally for the eight separate (1)H resonances in a (1)H (500 MHz) DQ CRAMPS solid-state (12.5 kHz MAS) NMR spectrum of the dipeptide beta-AspAla (S. P. Brown, A. Lesage, B. Elena, and L. Emsley, J. Am. Chem. Soc., 2004, 126, 13230). The simulation in SPINEVOLUTION (M. Veshtort and R. G. Griffin, J. Magn. Reson., 2006, 178, 248) of t(1) ((1)H DQ evolution) FIDs for clusters of eight dipolar-coupled protons gives separate simulated (1)H DQ build-up curves for the CH(2)(a), CH(2)(b), CH(Asp), CH(Ala), NH and OH (1)H single-quantum (SQ) (1)H resonances. An analysis of both the simulated and experimental (1)H DQ build-up leads to the following general observations: (i) considering the build-up of (1)H DQ peaks at a particular SQ frequency, maximum intensity is observed for the DQC corresponding to the shortest H-H distance; (ii) for the maximum intensity (1)H DQ peak at a particular SQ frequency, the recoupling time for the observed maximum intensity depends on the corresponding H-H distance, e.g., maximum intensity for the CH(2)(a)-CH(2)(b) (H-H distance = 1.55 A) and OH-CH(Asp) (H-H distance = 2.49 A) DQ peaks is observed at n(rcpl) = 2 and 3, respectively; (iii) for DQ peaks involving a CH(2) proton at a non-CH(2) SQ frequency, there is much reduced intensity and a maximum intensity at a short recoupling time; (iv) for the other lower intensity (1)H DQ peaks at a particular SQ frequency, maximum intensity is observed for the same (or close to the same) recoupling time, but the relative intensity of the DQ peaks is a reliable indicator of the relative H-H distance-the ratio of the maximum intensities for the peaks at the CH(Ala) SQ frequency due to the two DQCs with the NH and OH protons are found to be approximately in the ratio of the squares of the corresponding dipolar coupling constants. While the simulated (1)H DQ build-up curves reproduce most of the features of the experimental curves, maximum intensity is often observed at a longer recoupling time in simulations. In this respect, simulations for two to eight spins show a trend towards a faster decay for an increasing number of considered spins. Finally, simulations show that increasing either the Larmor frequency (to 1 GHz) or the MAS frequency (to 125 kHz) does not lead to changes in the marked differences between the (1)H DQ build-up curves at the CH(Asp) SQ frequency for DQCs to the CH(2)(a) and OH protons that correspond to similar H-H distances (2.39 A and 2.49 A, respectively).

Download full-text PDF

Source
http://dx.doi.org/10.1039/b906400aDOI Listing

Publication Analysis

Top Keywords

maximum intensity
28
h-h distance
16
recoupling time
16
build-up curves
12
intensity observed
12
intensity
10
peaks
8
correlation peaks
8
mas nmr
8
peaks observed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!