A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the Cepheid respiratory syncytial virus and influenza virus A/B real-time PCR analyte specific reagent. | LitMetric

Evaluation of the Cepheid respiratory syncytial virus and influenza virus A/B real-time PCR analyte specific reagent.

J Virol Methods

Health Protection Agency Newcastle Laboratory, Institute of Pathology, Newcastle General Hospital, Westgate Road, Newcastle upon Tyne NE4 6BE, UK.

Published: December 2009

Two rapid real-time RT-PCR assays, specific for respiratory syncytial virus (RSV) and influenza A and B, were evaluated for the detection of these viruses in clinical respiratory samples. The RSV assay was applied to 100 samples and the Influenza A and B assay applied to 96 samples all of which had been tested previously by an "in-house" multiplex real-time PCR assay. Forty-three samples were negative for RSV by both methods and 56 samples were positive by both methods. One sample was negative by the new RSV assay although it was positive for RSV A by the "in-house" test. Thirty-nine samples were negative for influenza virus by both methods and 55 samples were positive by both assays. Two samples were negative by the new influenza assay however they were positive by the "in-house" influenza assay. The new assays did not cross react with samples containing other viruses including parainfluenza 1, 2, and 4; human metapnuemovirus; coronavirus 229E, NL63, OC43; rhinovirus; adenovirus; bocavirus and had a specificity of 100% and a sensitivity of 98.2% for RSV and 96.5% for influenza respectively. The results of this study demonstrate that the new assays are specific and sensitive for the detection of RSV and influenza viruses in clinical samples.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7119759PMC
http://dx.doi.org/10.1016/j.jviromet.2009.07.020DOI Listing

Publication Analysis

Top Keywords

influenza assay
12
samples negative
12
samples
10
respiratory syncytial
8
syncytial virus
8
influenza
8
influenza virus
8
real-time pcr
8
assays specific
8
rsv influenza
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!